2017
DOI: 10.1002/jcla.22188
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of di‐potassium and tri‐potassium EDTA evacuated tubes for routine haematological testing

Abstract: Background The influence of blood collection devices on laboratory tests is often overlooked. We have discussed here how blood collection materials and devices can alter haematological test results, with an emphasis on blood collection tube (BCT) additives. We have compared K2 & K3‐EDTA vacuum tubes of same manufacturer IMPROVACUTER ® for CBC analysis. Methods Blood was collected in both tubes simultaneously. Samples were analysed immediately after collection (<15 minutes) and after 4 hours by MEK−6318J/K Haem… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
6
0
2

Year Published

2018
2018
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 18 publications
(9 citation statements)
references
References 17 publications
1
6
0
2
Order By: Relevance
“…However, error aspect for studies in the pre analytical phase requires considerable attention on procedures like blood sample collection, identification of patients, selection of proper blood collection vials, accurate blood suction, specimen labeling, clerical error and storage. Work by many others shows that 93% of errors does not relate to the high standard analytical method [2][3][4]. Central laboratories have been established in many countries in addition to local initiative hospital laboratories.…”
Section: Introductionsupporting
confidence: 44%
“…However, error aspect for studies in the pre analytical phase requires considerable attention on procedures like blood sample collection, identification of patients, selection of proper blood collection vials, accurate blood suction, specimen labeling, clerical error and storage. Work by many others shows that 93% of errors does not relate to the high standard analytical method [2][3][4]. Central laboratories have been established in many countries in addition to local initiative hospital laboratories.…”
Section: Introductionsupporting
confidence: 44%
“…EDTA is a widely used anticoagulant for whole blood routine hematologic examination ( 10 ), proposed by the International Council for Standardization in Hematology (ICSH). Since Shreiner and Bell first defined a phenomenon of platelet aggregation directly attributed to EDTA anticoagulant ( 1 ), numerous cases of EDTA-PTCP have been reported in patients with immune thrombocytopenic purpura ( 11 ), dengue infection ( 12 ), scrub typhus infection ( 13 ), sepsis ( 14 ), gastrectomy ( 15 ), neuroendocrine carcinoma ( 16 ), etc.…”
Section: Discussionmentioning
confidence: 99%
“…From each participant,2 ml of whole blood was needed to be collected from the venous blood directly into an EDTA containing tube, this procedure was done under sterile conditions [19].…”
Section: Blood Samplingmentioning
confidence: 99%