This manuscript exemplifies the prospective use of asymmetrical flow field flow fractionation (AF4) coupled to ICP-MS as a simple tool for chemical speciation of selemethionine in selenized yeast.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 41 publications
0
3
0
Order By: Relevance
“…In this line, the use of AF 4 -ICP-MS is presented for rst time for the determination of SeMet in selenised yeast. 165 Selenium was released from samples by using different sample treatment protocols including: extraction with; 4 mol L À1 methane sulfonic acid with and without reux, formic acid, alkaline extraction using SDS, water and UAE (both probe and bath) with water. In order to achieve complete recoveries, the AF 4 membrane pore size and interactions between analyte and membrane were taken into consideration.…”
Section: Seleniummentioning
confidence: 99%
“…In this line, the use of AF 4 -ICP-MS is presented for rst time for the determination of SeMet in selenised yeast. 165 Selenium was released from samples by using different sample treatment protocols including: extraction with; 4 mol L À1 methane sulfonic acid with and without reux, formic acid, alkaline extraction using SDS, water and UAE (both probe and bath) with water. In order to achieve complete recoveries, the AF 4 membrane pore size and interactions between analyte and membrane were taken into consideration.…”
Section: Seleniummentioning
confidence: 99%
“…Three reviews addressing different topics that appear in later sections of this update relate to advances in single-cell ultra-trace analysis, 23 asymmetrical flow field flow coupled to fractionation ICP-MS 24 and consideration of blood Ti concentrations as a marker for orthopaedic implant wear. 25…”
Section: Reviewsmentioning
confidence: 99%
“…The procedure for total As, determined by ICP-MS (with O 2 reaction gas) following microwave-assisted digestion (quartz vessels and 200 °C) with HNO 3 –H 2 O 2 , was validated by the analysis of the Nuclear Chemistry and Technology Institute (Warsaw, Poland) Control Material CS-M-3 (microelements in mushroom powder). Several sample preparation methods were evaluated 24 for the determination of SeMet in selenized yeast by asymmetric flow FFF ICP-MS. The seven procedures were extraction with methanesulfonic acid (with and without reflux step), room temperature extraction with HCOOH, alkaline extraction with SDS, and H 2 O extraction (both manual and ultrasound-assisted).…”
Section: Sample Collection and Preparationmentioning
confidence: 99%