2004
DOI: 10.1002/ep.10005
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of industrial biotrickling filter at the flexographic printing facility

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
13
0

Year Published

2005
2005
2012
2012

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(16 citation statements)
references
References 4 publications
3
13
0
Order By: Relevance
“…30 The results obtained with the coupled system improved the performance considerably, so the RE increased up to 95% ( Figure 5) for an EBRT of 24 sec, and the VOC biotrickling emission was within the regulation requirements, with the VOC concentration level always below 40 mg-C/m 3 ( Figure 6, c and d, and Figure 7). These results were in good agreement with those previously reported for similar coupled systems (activated carbon prefilter plus biological reactor) on bench and industrial scales, 8,27,28 and it denoted that this coupled system was especially appropriate for the VOC removal of very uneven airstreams.…”
Section: Resultssupporting
confidence: 92%
See 3 more Smart Citations
“…30 The results obtained with the coupled system improved the performance considerably, so the RE increased up to 95% ( Figure 5) for an EBRT of 24 sec, and the VOC biotrickling emission was within the regulation requirements, with the VOC concentration level always below 40 mg-C/m 3 ( Figure 6, c and d, and Figure 7). These results were in good agreement with those previously reported for similar coupled systems (activated carbon prefilter plus biological reactor) on bench and industrial scales, 8,27,28 and it denoted that this coupled system was especially appropriate for the VOC removal of very uneven airstreams.…”
Section: Resultssupporting
confidence: 92%
“…As previously reported, 8,27 to control the VOC concentration spikes arising from sudden variations in the paint operation, and to modulate the high and low pollutant loads, a filter of activated carbon can be used. Because biological treatments run better when inlet conditions are stable, the use of active carbon as a buffer unit usually improves the bioreactor performance.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…8 -12 Biotrickling filter technology has received increasing research attention. 7,[13][14][15][16] Many researchers adopted the process to treat the nitrogen oxides (NO x )-contaminated gas via denitrification. 17,18 This process relies on the maintenance of anoxic conditions so that NO x can be converted into inert N gas.…”
Section: Introductionmentioning
confidence: 99%