2011
DOI: 10.1016/j.jcmg.2010.09.020
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of LV Diastolic Function From Color M-Mode Echocardiography

Abstract: early diastolic flow propagation occurs with an initial rapid velocity that abruptly decelerates to a terminal velocity. With diastolic dysfunction, the initial velocity is slower and the deceleration point occurs closer to the mitral annulus than with normal filling. A new parameter that combines these 2 effects (Vs) provides a more accurate assessment of diastolic function than the conventional propagation velocity.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
41
1

Year Published

2012
2012
2017
2017

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 46 publications
(44 citation statements)
references
References 38 publications
2
41
1
Order By: Relevance
“…At the one-third measurement position, the short travelling distance of the inflow jet from the MLT produced unsteady flow propagation. This had been demonstrated by another study that the V p measured close to MLT was unable to accurately identify the diastolic dysfunction [34]. In addition to the low temporal resolution of PC-MRI, a negligible or zero time delay was frequently encountered at one-third measurement position, making the estimation of V p impossible.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…At the one-third measurement position, the short travelling distance of the inflow jet from the MLT produced unsteady flow propagation. This had been demonstrated by another study that the V p measured close to MLT was unable to accurately identify the diastolic dysfunction [34]. In addition to the low temporal resolution of PC-MRI, a negligible or zero time delay was frequently encountered at one-third measurement position, making the estimation of V p impossible.…”
Section: Discussionmentioning
confidence: 99%
“…Since LV sizes vary with cardiac health [34] and between healthy ethnic groups [3], we had inspected V p values at a number of distances away from MLT. At the one-third measurement position, the short travelling distance of the inflow jet from the MLT produced unsteady flow propagation.…”
Section: Discussionmentioning
confidence: 99%
“…5 The CMMD data was used to integrate the one-dimensional Euler equation as previously described. 5,8 The pressure difference at each point along with the scan line was measured relative to left atrium just above the mitral valve at the mitral annulus just before mitral valve opening by calculating the line integral between them. From the temporal profile of the IVPD, the peak IVPD from the left atrium to LV apex was calculated.…”
Section: Analysis Of the Intraventricular Pressure Differencementioning
confidence: 99%
“…This method has been validated by comparison to direct measurements with micromanometers 15, 16 and tested clinically in patients with diastolic dysfunction, dilated cardiomyopathy, and systolic HF. 5,15,17 …”
Section: Analysis Of the Intraventricular Pressure Differencementioning
confidence: 99%