2016
DOI: 10.1371/journal.pone.0164521
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of New Calibrated Pulse-Wave Analysis (VolumeViewTM/EV1000TM) for Cardiac Output Monitoring Undergoing Living Donor Liver Transplantation

Abstract: BackgroundIntrapulmonary thermodilution technique using a pulmonary artery catheter is widely used for measuring cardiac output (CO) in patients undergoing liver transplantation. However, its invasiveness and associated complications have led to an interest in less invasive modalities. Thus, we aimed to evaluate whether the new calibrated pulse-wave analysis method monitoring (VolumeViewTM/EV1000TM) is interchangeable with intrapulmonary thermodilution technique.MethodsTwenty-eight patients undergoing living d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2018
2018
2019
2019

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 32 publications
0
8
0
Order By: Relevance
“…Those pre-existing devices did not show their best performance at the time when they were needed most. We are inclined to place emphasis on the fact that such major fluctuations in vascular tone might negatively influence the performance of the EV1000 method as evidenced by several studies [2,5]. In contrast, within a systemic vascular resistance range of 400 to 1300 dyne∙s/cm 5 , the correlation coefficient was 0.840, which implies that a consistent performance was provided by the DL model.…”
Section: Discussionmentioning
confidence: 98%
See 2 more Smart Citations
“…Those pre-existing devices did not show their best performance at the time when they were needed most. We are inclined to place emphasis on the fact that such major fluctuations in vascular tone might negatively influence the performance of the EV1000 method as evidenced by several studies [2,5]. In contrast, within a systemic vascular resistance range of 400 to 1300 dyne∙s/cm 5 , the correlation coefficient was 0.840, which implies that a consistent performance was provided by the DL model.…”
Section: Discussionmentioning
confidence: 98%
“…Recently, less invasive commercially available arterial pressure waveform-based SV measuring methods (e.g., EV1000; Edwards Lifescience, Irvine, CA, USA) have become popular [2]. The arterial waveform analysis generally is considered to be minimally invasive and provides continuous data that enable a prompt response to be initiated.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Whether there is an additional benefit to decision making provided by a PAC over standard care in elderly, high-risk surgical patients requiring intensive care [ 6 9 ] is questionable. That said, the importance of intraoperative CO monitoring has led to the development of non-invasive or less-invasive cardiac output monitors, which appear promising as replacements for the thermodilution technique in the intensive care unit; however, none of them can provide adequate precision and accuracy during LDLT [ 10 12 ].…”
Section: Introductionmentioning
confidence: 99%
“…Measurements of central venous and pulmonary capillary wedge-pressures have traditionally been used to try and identify hypovolaemia post liver transplantation but both values are known to be limited in their ability to do this [ 15 ]. Less invasive pulse-contour analysis devices, such as the FloTrac (EV1000) device, have been used for cardiac output measurement with reasonable accuracy in patients undergoing liver transplantation [ 16 , 17 ]. Whilst there are many donor and recipient factors that contribute to graft and patient survival [ 18 , 19 ], optimal perfusion of the graft is the final common pathway for many of the factors influencing outcome and optimising hepatic blood flow following liver transplant has been shown to result in improved graft function [ 20 ].…”
Section: Introductionmentioning
confidence: 99%