1979
DOI: 10.1366/0003702794925011
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Axially Viewed (End-on) Inductively Coupled Argon Plasma Source for Atomic Emission Spectroscopy

Abstract: A comparison of an “end-on” viewed argon inductively coupled plasma (ICP) operated in the horizontal position with the conventional “side-on” viewed argon ICP was carried out using the same experimental setup. The end-on ICP required an air cutoff stream located toward the tip of the luminous discharge, to protect the optics and to increase linearity ranges, and the orifice diameter of the central tube of the torch was widened to 1.9 mm, to improve line/background ratios. With the end-on viewed plasma the line… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

6
13
0

Year Published

1995
1995
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 56 publications
(19 citation statements)
references
References 4 publications
6
13
0
Order By: Relevance
“…The fact that there was little overall difference among the three sets of experimental conditions suggests that the shear gas was effective in minimizing the effect of self-absorption in the axial viewing arrangement. These results are in agreement with the work of Demers [3] and confi rm that axial viewing shifted the linear range to lower concentrations while retaining a similar span in concentration as radial viewing.…”
Section: Linear Working Range For CDsupporting
confidence: 91%
See 4 more Smart Citations
“…The fact that there was little overall difference among the three sets of experimental conditions suggests that the shear gas was effective in minimizing the effect of self-absorption in the axial viewing arrangement. These results are in agreement with the work of Demers [3] and confi rm that axial viewing shifted the linear range to lower concentrations while retaining a similar span in concentration as radial viewing.…”
Section: Linear Working Range For CDsupporting
confidence: 91%
“…Useful positions for the shearing gas nozzle were found to be in the range between 29 and 34 mm beyond the load coil. This coincided with the region identified by Demers [3] as the visible boundary between the normal analytical zone and the plume when introducing high concentrations of yttrium.…”
Section: Instrumentationsupporting
confidence: 84%
See 3 more Smart Citations