2018
DOI: 10.1111/cid.12611
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the effect of self‐cutting and nonself‐cutting thread designed implant with different thread depth on variable insertion torques: An histomorphometric analysis in rabbits

Abstract: The effect of the depth of the thread design was significant for the power-shaped design in enhancing BIC when compared with V-shaped thread design. With high torque V-shaped thread design had more new bone formation as compared with power-shaped thread design.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 28 publications
0
2
0
Order By: Relevance
“…Different insertion torque values have been tested both in human [79] and in animals studies [1, 46, 1012]. A systematic review with meta-analyses summarized data from both animal and human studies and two groups were identified based on the insertion toque values: > 25 Ncm or < 30 Ncm [13].…”
Section: Introductionmentioning
confidence: 99%
“…Different insertion torque values have been tested both in human [79] and in animals studies [1, 46, 1012]. A systematic review with meta-analyses summarized data from both animal and human studies and two groups were identified based on the insertion toque values: > 25 Ncm or < 30 Ncm [13].…”
Section: Introductionmentioning
confidence: 99%
“…Other studies reported higher bone resorption around implants with high insertion torque [17,18,[33][34][35][36]. On the other hand, several studies, among them animal models [14,30,[37][38][39][40][41][42] and human studies [15,[43][44][45][46][47][48][49][50][51] analyzed the outcomes of high insertion torques, most of them equal or greater than 70Ncm, with the same parameters used in the present study; all these studies reported no significant differences between conventional and high insertion torques regarding success rates and/or marginal bone levels. Also, systematic reviews with metaanalyses [52][53][54][55][56] have also been published about high insertion torques; they observed no significant difference in marginal bone resorption and implant failure rate between implants inserted with high, regular or low insertion torque values.…”
Section: Discussionmentioning
confidence: 99%