2016
DOI: 10.1016/j.fsigen.2015.09.009
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Illumina ® Beta Version ForenSeq™ DNA Signature Prep Kit for use in genetic profiling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

19
167
1
1

Year Published

2016
2016
2020
2020

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 201 publications
(188 citation statements)
references
References 18 publications
19
167
1
1
Order By: Relevance
“…SNP coverage for HID-Ion is affected by the number of wells in the sequencing chip which are occupied by Ion Sphere™ Particles (ISP) with monoclonally amplified SNP target that were successfully read 21 . On the other hand, SNP coverage for the MiSeq ® FGx™ is affected by the PCR amplification efficiency, purification, and bead-based library normalization 11 . Increased number of markers multiplexed in one sequencing reaction could also increase variation in coverage of the SNP markers 11 .…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…SNP coverage for HID-Ion is affected by the number of wells in the sequencing chip which are occupied by Ion Sphere™ Particles (ISP) with monoclonally amplified SNP target that were successfully read 21 . On the other hand, SNP coverage for the MiSeq ® FGx™ is affected by the PCR amplification efficiency, purification, and bead-based library normalization 11 . Increased number of markers multiplexed in one sequencing reaction could also increase variation in coverage of the SNP markers 11 .…”
Section: Resultsmentioning
confidence: 99%
“…On the other hand, SNP coverage for the MiSeq ® FGx™ is affected by the PCR amplification efficiency, purification, and bead-based library normalization 11 . Increased number of markers multiplexed in one sequencing reaction could also increase variation in coverage of the SNP markers 11 . Comparison of the markers’ SNP coverage between the two MPS systems (Figs 2 and 3) showed that MiSeq ® FGx™ achieved higher SNP coverage reads in majority of the markers; however, it also showed higher variation in SNP coverage distribution across samples than the HID-Ion PGM™, with more read outliers observed in the univariate statistical evaluation.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…To ascertain which of the explanations have more support, i.e., wrong categorization of the samples before entering the laboratory or a failure of the panel to resolve, these eight samples were analyzed using the MiSeq FGx Forensic Genomics System. The panel of primers included in the ForenSeq TM DNA Signature Prep Kit (used for library generation) contains 56 AIMs [17] (Supplemental Figure 4, Table 3). African American sample 20882 was classified as Hispanic American by our AIMs panel and the ForenSeq TM panel.…”
Section: Resultsmentioning
confidence: 99%
“…SNP typing of eight questionable samples (by ancestry assignment) were analyzed using the Illumina ForenSeq™ DNA Signature Prep Kit as described by Churchill et al [17]. The ancestry assignments between our AIMs panel and that by the AIMs contained within the ForenSeq™ kit were compared for resolving non-concordant population affinity.…”
Section: Concordance Datamentioning
confidence: 99%