2015
DOI: 10.1109/jphotov.2015.2479464
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the PV Cell Operation Temperature in the Process of Fast Switching to Open-Circuit Mode

Abstract: Abstract-A procedure for measuring the overheating temperature (AT) of a p-n junction area in the structure of photovoltaic (PV) cells converting laser or solar radiations relative to the ambient temperature has been proposed for the conditions of connecting to an electric load. The basis of the procedure is the measurement of the open-circuit voltage (Voc ) during the initial time period after the fast disconnection of the external resistive load. The simultaneous temperature control on an external heated par… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
4
0
7

Year Published

2016
2016
2019
2019

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(11 citation statements)
references
References 15 publications
0
4
0
7
Order By: Relevance
“…At such light switching, the expected voltagetime dependence should have a shape of a rectangular triangle due to a gradual temperature rise [6][7][8] (if the transition electric processes in the p-n junction and in equipment are neglected). The triangle acute apex gives the required value of the not heated p-n junction voltage.…”
Section: Procedures For Obtaining the Corrected V Oc -J G Dependencementioning
confidence: 99%
See 1 more Smart Citation
“…At such light switching, the expected voltagetime dependence should have a shape of a rectangular triangle due to a gradual temperature rise [6][7][8] (if the transition electric processes in the p-n junction and in equipment are neglected). The triangle acute apex gives the required value of the not heated p-n junction voltage.…”
Section: Procedures For Obtaining the Corrected V Oc -J G Dependencementioning
confidence: 99%
“…The V oc drop is strictly linear, which also proves the constancy of the incident power after t 0 (light switching moment). The linear dependence of V oc on temperature is well known [6][7][8], which makes easier to extrapolate V oc before the zero moment of time t 0 . The dependence of extrapolated V oc values on J g is presented in Fig.2b (black line).…”
Section: Procedures For Obtaining the Corrected V Oc -J G Dependencementioning
confidence: 99%
“…Многокомпонентные твердые растворы соединений A III B V могут служить основой гетероструктур для эффективных оптоэлектронных приборов [1][2][3][4][5][6][7][8][9][10][11][12][13][14]. Необходимым условием этого является получение совершенных по структуре эпитаксиальных слоев твердых растворов соединений A III B V и совмещение их по периоду решетки с бинарными соединениями, обладающими требуемыми электрофизическими характеристиками.…”