2015
DOI: 10.1016/j.joen.2015.07.009
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Shaping Characteristics of ProTaper Gold, ProTaper NEXT, and ProTaper Universal in Curved Canals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

13
120
6
11

Year Published

2016
2016
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 152 publications
(168 citation statements)
references
References 30 publications
13
120
6
11
Order By: Relevance
“…Another possible explanation is the effect of the off-center cross-sectional design on PTN movement during canal preparation, especially at the second curvature of the S-shaped canals where the "swaggering movement" may become exaggerated. The overall flexibility and movement of PTN may have an unfavorable impact on the preparation outcome especially in S-shaped canals, however, studies on natural teeth found that the PTN produced significantly less canal transportation compared with PTU (38,39). Student perceptions of the PTN and PTU systems were explored in the questionnaire and results are shown in Table 1.…”
Section: Discussionmentioning
confidence: 99%
“…Another possible explanation is the effect of the off-center cross-sectional design on PTN movement during canal preparation, especially at the second curvature of the S-shaped canals where the "swaggering movement" may become exaggerated. The overall flexibility and movement of PTN may have an unfavorable impact on the preparation outcome especially in S-shaped canals, however, studies on natural teeth found that the PTN produced significantly less canal transportation compared with PTU (38,39). Student perceptions of the PTN and PTU systems were explored in the questionnaire and results are shown in Table 1.…”
Section: Discussionmentioning
confidence: 99%
“…The PTG system has a different geometry; smaller dimensions, an off-centered mass, and a regressive taper. The centering ability of PTG instruments may ensure that a greater percentage of dentin thickness is retained in the root canal and may facilitate greater bacteria elimination (27). The convex triangular cross-section and progressive taper enhance the cutting efficacy of PTG, while decreasing rotational friction between the file blade and dentin (28).…”
Section: Discussionmentioning
confidence: 99%
“…Desde então, vários estudos aplicaram diferentes metodologias para essa avaliação, como uso de canais artificias 47,48 ou de dentes humanos. A avaliação pré e pós-instru-mentação também difere entre os estudos, com a utilização de imagens radiográficas periapicais 49 , microscopia eletrônica de varredura 50 e, mais recentemente, por meio de tomografia computadorizada de feixe cônico 27,41 , além de por microtomografia computadorizada 27,[51][52][53] .…”
Section: Discussionunclassified