2018
DOI: 10.1038/s41598-018-32207-6
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of two-point Dixon water-fat separation for liver specific contrast-enhanced assessment of liver maximum capacity

Abstract: Gadoxetic acid-enhanced magnetic resonance imaging has become a useful tool for quantitative evaluation of liver capacity. We report on the importance of intrahepatic fat on gadoxetic acid-supported T1 mapping for estimation of liver maximum capacity, assessed by the realtime 13C-methacetin breathing test (13C-MBT). For T1 relaxometry, we used a respective T1-weighted sequence with two-point Dixon water-fat separation and various flip angles. Both T1 maps of the in-phase component without fat separation (T1_in… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 32 publications
0
2
0
Order By: Relevance
“…Water 1 H R 1 is multiexponential, particularly with sequences where macromolecule-associated fast-relaxing water contributes to the measurement. Other substances in the liver may also contribute to the 1 H signal, such as glycogen [87] or triglyceride [76,131]. Inflowing blood [110,132], physiologic motion [71], magnetization transfer, and iron affect the measured R 1 in ways which depend both on the sequence and on the analysis employed.…”
Section: Discussionmentioning
confidence: 99%
“…Water 1 H R 1 is multiexponential, particularly with sequences where macromolecule-associated fast-relaxing water contributes to the measurement. Other substances in the liver may also contribute to the 1 H signal, such as glycogen [87] or triglyceride [76,131]. Inflowing blood [110,132], physiologic motion [71], magnetization transfer, and iron affect the measured R 1 in ways which depend both on the sequence and on the analysis employed.…”
Section: Discussionmentioning
confidence: 99%
“…The other limitation of this study is that we investigated the proposed method on T1-weighted MRI without fat saturation, which is not commonly used as diagnostic MRI in the abdominal area. Instead, fat suppression techniques have been routinely used for upper abdomen (Reeder and Sirlin 2010, Beddy et al 2011, Brandão et al 2013, Li et al 2014b, Haimerl et al 2018. For instance, fat suppression can be utilized to improve visualization of the uptake of contrast material through suppressing the signal from normal adipose tissue.…”
Section: Discussionmentioning
confidence: 99%