2002
DOI: 10.1541/ieejpes1990.122.4_554
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation study about Redox flow battery response and its modeling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
19
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 28 publications
(22 citation statements)
references
References 0 publications
0
19
0
Order By: Relevance
“…The Redox Flow Batteries are incorporated in the power system to meet the load frequency control problems and to ensure an improved power quality. With the excellent short-time overload output and response characteristics possessed by RFB in particular [12][13][14], the effects of generation control and the absorption of power fluctuation required for power quality maintenance as expected be achieved with the incorporation of RFB unit. The Redox Flow Batteries are capable of ensuring a very fast response and therefore, hunting due to a delay in response does not occur.…”
Section: Mathematical Modeling Of Redox Flow Batteriesmentioning
confidence: 99%
See 1 more Smart Citation
“…The Redox Flow Batteries are incorporated in the power system to meet the load frequency control problems and to ensure an improved power quality. With the excellent short-time overload output and response characteristics possessed by RFB in particular [12][13][14], the effects of generation control and the absorption of power fluctuation required for power quality maintenance as expected be achieved with the incorporation of RFB unit. The Redox Flow Batteries are capable of ensuring a very fast response and therefore, hunting due to a delay in response does not occur.…”
Section: Mathematical Modeling Of Redox Flow Batteriesmentioning
confidence: 99%
“…In order to compensate for sudden load changes, an active power source with fast response such as Redox Flow Batteries (RFB) has a wide range of applications such as power quality maintenance of decentralized power supplies. The RFB has effectively short-time overload output and have efficient response characteristics in the particular [12][13][14]. In this study, BFO algorithm is used to optimize the PI controller gains for LFC of a Two-Area Thermal Reheat Interconnected Power System (TATRIPS) in a restructured environment with and without RFB unit.…”
Section: Introductionmentioning
confidence: 99%
“…Battery energy storage [5,20] is very helpful in meeting the sudden load requirements and is effective in improving transient response of frequency and tie line power deviations. A variety of energy storage systems like SMES, BES, CES, RFB have been used in the LFC systems [18][19][20][21][22][23][24][25]. SMES has been applied to LFC problem by many researchers [18,19,21].…”
Section: Introductionmentioning
confidence: 99%
“…SMES has been applied to LFC problem by many researchers [18,19,21]. Rechargeable batteries such as RFB are equivalent to SMES and gaining momentum in research due to their fast and outstanding performance [5, [22][23][24][25] Representing a control area of power systems with multisources like hydro, thermal, gas, nuclear etc is more pragmatic [4,17,[28][29][30]. Most probably, Ramakrishna and Bhatti [28] have introduced first the LFC analysis using multi-source power generation in a control area.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation