Evolution of Analytical Performance in Portable Glucose Meters in the Last Decade

Abstract: OBJECTIVE -To assess and compare the technical accuracy of portable glucose meters during the last decade.RESEARCH DESIGN AND METHODS -One-thousand preprandial (pre) and postprandial (post) capillary whole-blood glucose values measured with meters owned mainly by diabetic patients were compared with a single laboratory method yearly from 1989 to 1999. A total of 21,950 capillary measurements and their corresponding laboratory reference values were analyzed at our clinic.RESULTS -The lowest mean absolute differ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
12
0
11

Year Published

2004
2004
2022
2022

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 42 publications
(23 citation statements)
references
References 24 publications
(23 reference statements)
0
12
0
11
Order By: Relevance
“…Moreover, meters store up to several hundred results that can subsequently be downloaded for analysis. Together, these improvements have improved the performance of new meters (122,123 ). Nonetheless, meter performance in the hands of patients does not equal potential performance as judged by performance in the hands of skilled medical technologists (124 ).…”
Section: Gppmentioning
confidence: 99%
“…Moreover, meters store up to several hundred results that can subsequently be downloaded for analysis. Together, these improvements have improved the performance of new meters (122,123 ). Nonetheless, meter performance in the hands of patients does not equal potential performance as judged by performance in the hands of skilled medical technologists (124 ).…”
Section: Gppmentioning
confidence: 99%
“…Certains PAQ utilisent du plasma capillaire sur fluorure [11]. Récemment, certains auteurs [27] préconisent l'utilisation de l'iodoacétate comme antiglycolytique, car il intervient à la cinquième étape de la cascade de la glycolyse, au lieu de la huitième pour le fluorure ; mais même avec cet antiglycolytique, la décroissance du glucose plasmatique suit une pente de 9 %, pendant les deux premières heures, avant que l'effet se fasse sentir.…”
Section: Choix Du Type De Prélèvementunclassified
“…Ces critères sont moins drastiques dans les recommandations de l'Alfediam (Association française d'étude du diabète et des maladies métaboliques) [17] : CV maximal de 10 % quelle que soit la valeur de la glycémie ; ils sont retenus dans certaines évaluations [11,24,64].…”
Section: Choix Du CV Et Des Approches Statistiquesunclassified
“…4 The test bias of whole blood samples with the same plasma glucose but different Hct may be þ50% or higher, a large challenge for conventional glucose test strip manufacturers. 5 On the other hand, a blood sample collected from the fingertip can be as small as several microliters. Thus, it is difficult for a lay user to separate the plasma sample in a test.…”
mentioning
confidence: 99%