2007
DOI: 10.1016/j.nucengdes.2007.02.018
|View full text |Cite
|
Sign up to set email alerts
|

Evolution of the structure of a gas–liquid two-phase flow in a large vertical pipe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
60
0
1

Year Published

2008
2008
2023
2023

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 103 publications
(64 citation statements)
references
References 16 publications
2
60
0
1
Order By: Relevance
“…Prasser et al, 1998Prasser et al, , 2001) and on experiments using the wire-mesh sensor (e.g. Prasser et al 2002, 2007b, Lucas et al 2005, 2007. One measuring plane of the sensor consists of two grids of parallel wires, which span over the measurement cross-section.…”
Section: Wire-mesh Sensormentioning
confidence: 99%
See 1 more Smart Citation
“…Prasser et al, 1998Prasser et al, , 2001) and on experiments using the wire-mesh sensor (e.g. Prasser et al 2002, 2007b, Lucas et al 2005, 2007. One measuring plane of the sensor consists of two grids of parallel wires, which span over the measurement cross-section.…”
Section: Wire-mesh Sensormentioning
confidence: 99%
“…At relatively small void fractions, the pressure effect on the increase in bubble size can have a larger influence on the evolution of the bubble size distribution than coalescence and fragmentation. Prasser et al 2007b discuss which essential influence the bubble expansion may have on the bubble size distribution basing on experimental and numerical results.…”
Section: Introductionmentioning
confidence: 99%
“…As it was mentioned before, the experimental data used for the validation of the present model have been taken at the thermal-dynamic test facility TOPFLOW [Schaffrath et al, 2001;Prasser et al,2007] at the Institute of Safety Research of Forschungszentrum Rossendorf e.V. The name, TOPFLOW, is an acronym for transient TwO Phase FLOW.…”
Section: Experimental Setup and Conditionsmentioning
confidence: 99%
“…To that end the so-called "variable gas injection system" at the TOPFLOW facility was constructed [13]. It is a 9 m tall vertical pipe of 200 mm nominal diameter, which is equipped with gas injection units at six different heights.…”
Section: Evolution Of a Gas-liquid Two-phase Flow In A Vertical Pipementioning
confidence: 99%
“…As shown in Fig. 10, the result of the lift force inverse according to Tomiyama [14] can be studied in a polydisperse bubbly flow (compare [13]). Small bubbles still form a wall peak, even when the total gas fraction profile has a central peak.…”
Section: Evolution Of a Gas-liquid Two-phase Flow In A Vertical Pipementioning
confidence: 99%