Background: Early plasma transfusion is life-saving for bleeding trauma patients. Freeze-dried plasma (FDP) provides unique formulation advantages for infusion in the prehospital setting. We describe characterization and clinical safety data of the first, next-generation FDP stored in plastic bags with rapid reconstitution. Study design and methods: Coagulation and chemistry parameters on 155 pairs of fresh frozen plasma (FFP) and their derivative FDP units were compared. Next, a first-in-human, dose-escalation safety evaluation of FDP, involving 24 healthy volunteers who donated either whole blood or apheresis plasma to create autologous FDP, was performed in three dose cohorts (270, 540, and 810 ml) and adverse events (AEs) were monitored. Cohort 3 was randomized, double-blind with a cross-over arm that compared FDP versus FFP using descriptive analysis for AEs, coagulation, hematology, and chemistry parameters.Results: FDP coagulation factors, clotting times, and product quality (pH, total protein, and osmolality) post-lyophilization were preserved. FDP infusions, of up to 810 ml per subject, were found to be safe and with no serious