2019
DOI: 10.1016/j.ijrefrig.2019.01.016
|View full text |Cite
|
Sign up to set email alerts
|

Exergoeconomic performance comparison of R1234yf as a drop-in replacement for R134a in a domestic refrigerator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(9 citation statements)
references
References 21 publications
0
9
0
Order By: Relevance
“…The R407F also shows a COP higher than the R404A. Both refrigerants contain R32 (A2L) and R125 (A1) mixed in the same mass percentage as the A1 class of refrigerants mix [21].…”
Section: Evolution Of the Refrigerantmentioning
confidence: 96%
See 1 more Smart Citation
“…The R407F also shows a COP higher than the R404A. Both refrigerants contain R32 (A2L) and R125 (A1) mixed in the same mass percentage as the A1 class of refrigerants mix [21].…”
Section: Evolution Of the Refrigerantmentioning
confidence: 96%
“…Both refrigerants use polyol ester oil (POE), are Class A1 incombustible ( Figure 6), and has a lower toxicity. The R448A has a higher cooling capacity (Qe) than the R404A as it is composed of the hydrofluorocarbons (HFCs) R32 [6,21,23] and has a lower global warming potential (GWP) than the R404A, which is composed of hydrofluoroolefins (HFOs) by R1234yf and R1234ze (E) [24][25]. The result show a decrease in the global warming potential by 70%, and a COP higher than R404A [26], as shown in Figure 7 [27].…”
Section: R448a Refrigerantmentioning
confidence: 98%
“…The R1234ze and R1234yf are categorized as Class A2L with a low GWP, which is an alternative for R134A. and not for because the performance of R134A, R1234yf and R1234ze were similar [15][16][17]. Therefore, fourth generation refrigerants; R407A, R407F, R407H, R410A, R448A, R449A, R442A, R453A, and R463A, are refrigerants mixed with HFC, HFO, HC.…”
Section: Evolution Of the Refrigerantmentioning
confidence: 99%
“…They used two refrigerants, R134a and R1234yf, separately in the refrigerator-freezer, and exergy and exergoeconomic parameters were considered as comparative indicators. 8 Azhar and Altamush Siddiqui analyzed the comprehensive exergy of the parallel dual absorption refrigeration cycle using lithium bromide water as the working fluid. In addition, the parallel current was compared with the serial current for the same operational parameter.…”
Section: Introductionmentioning
confidence: 99%