1988
DOI: 10.1109/60.9358
|View full text |Cite
|
Sign up to set email alerts
|

Experience with PDA diagnostic testing on hydraulic generators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

1993
1993
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 72 publications
(11 citation statements)
references
References 2 publications
0
11
0
Order By: Relevance
“…Efforts were directed at improving the electronics of measuring systems [81,82]. Specially developed systems, such as the Canadian PDA [83,84] for on-line diagnostics of hydrogenerator stator windings, subdivide the selected amplitude range into a smaller number of broader channels (typically -30). In many of these systems pulses of opposite polarity are s e p arately stored and counted.…”
Section: Ieee Bansactions On Dielectrics and Electrical Hsulatianmentioning
confidence: 99%
“…Efforts were directed at improving the electronics of measuring systems [81,82]. Specially developed systems, such as the Canadian PDA [83,84] for on-line diagnostics of hydrogenerator stator windings, subdivide the selected amplitude range into a smaller number of broader channels (typically -30). In many of these systems pulses of opposite polarity are s e p arately stored and counted.…”
Section: Ieee Bansactions On Dielectrics and Electrical Hsulatianmentioning
confidence: 99%
“…Thus, they were merged to form the PRPD pattern reported in Figure 10. The visual inspection, [1,11], and the identification system, [67], applied to the pattern of Figure 10 provided the indication of "insulation-conductor delamination".…”
Section: Over-classification and Mergingmentioning
confidence: 99%
“…Synchronized multi-channel PD measurement systems, connected with multiple sensors, have been also proposed to reject both pulsating noise and PD cross-talk using the pulse-bypulse technique [11,13,14]. These solutions can reduce the influence of noise or disturbances but they are ineffective when applied to multiple PD sources.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…5. The NQN (Normalized Quantity Number) value is a measure of total energy released from partial discharges in one phase of a motor [4]. Table 3 shows the maximum, average, and minimum PD value resulting from the 500pF capacitors and the 80pF capacitors from the statistical analysis.…”
Section: Impact Of Coupler Typementioning
confidence: 99%