2019
DOI: 10.1016/j.est.2019.01.016
|View full text |Cite
|
Sign up to set email alerts
|

Experimental and numerical investigation of solar air heater with novel V-rib geometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 74 publications
(17 citation statements)
references
References 24 publications
0
17
0
Order By: Relevance
“…The maximum enhancement in Nu and TPF of the present study is compared with previous similar literature studies in Table 5. Trapezoidal ribs produce greater enhancement in Nu and TPF values than arc‐shaped ribs, 21 circular‐sectioned ribs, 8 perforated baffles, 43 and V‐shaped ribs 49 . Enhancement in the heat transfer values was obtained higher than Mahanand and Senapati 19 .…”
Section: Resultsmentioning
confidence: 87%
See 1 more Smart Citation
“…The maximum enhancement in Nu and TPF of the present study is compared with previous similar literature studies in Table 5. Trapezoidal ribs produce greater enhancement in Nu and TPF values than arc‐shaped ribs, 21 circular‐sectioned ribs, 8 perforated baffles, 43 and V‐shaped ribs 49 . Enhancement in the heat transfer values was obtained higher than Mahanand and Senapati 19 .…”
Section: Resultsmentioning
confidence: 87%
“…Trapezoidal ribs produce greater enhancement in Nu and TPF values than arc-shaped ribs, 21 circular-sectioned ribs, 8 perforated baffles, 43 and V-shaped ribs. 49 Enhancement in the heat transfer values was obtained higher than Mahanand and Senapati. 19 TER is found to be 4.24%, 8.17%, and 32.3% higher than, 8,43,57 respectively.…”
Section: Thermal Performance Factormentioning
confidence: 86%
“…In the present study, the SAH has been tested under the utilization of the wired ribs over the absorber. The used rib diameters are 1 mm and 2 mm so this one leads to make the values of relative roughness pitch P/e and relative roughness height e/D are (5,10,15,20,30) and (0.043, 0.086) respectively. The experimental procedure includes the testing of SAH under a wide range of the Re in order to cover Laminar and turbulent flow regions.…”
Section: Discussionmentioning
confidence: 99%
“…It is observed that the increase in Nu is associated with the increase of P/e values for both Figs. 6 and 7 [10]. The great values of P/e mean a reducing in the number of the wired ribs over the absorber and this lead to increase the area between each two ribs.…”
Section: Nu and Rementioning
confidence: 99%
“…Today, solar energy is well-intended because of its availability, cost-benefit, effectiveness, and sustainability in reducing carbon and poisonous gasses. Solar air heater (SAH) is an initial application that uses solar energy to absorb the energy irradiated on it (Singh Patel & Lanjewar, 2019). Solar energy absorption using SAH is a promising technology that makes use of solar energy.…”
Section: Introductionmentioning
confidence: 99%