Experimental Design of a Nonlinear Control Technique for Three-Phase Shunt Active Power Filter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
144
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 330 publications
(144 citation statements)
references
References 29 publications
0
144
0
Order By: Relevance
“…The power rating of the DSTATCOM is directly proportional to the current to be compensated and the dc-link voltage [9] . Generally, the dc-link voltage is maintained at much higher value than the maximum value of the phase-toneutral voltage in a three-phase four-wire system for satisfactory compensation (in a three-phase threewire system, it is higher than the phase-to-phase voltage) [2], [10]- [12] . However, a higher dc-link voltage increases the rating of the VSI, makes the VSI heavy, and results in higher voltage rating of insulated gate bipolar transistor (IGBT) switches.…”
Section: Introductionmentioning
confidence: 99%
“…The power rating of the DSTATCOM is directly proportional to the current to be compensated and the dc-link voltage [9] . Generally, the dc-link voltage is maintained at much higher value than the maximum value of the phase-toneutral voltage in a three-phase four-wire system for satisfactory compensation (in a three-phase threewire system, it is higher than the phase-to-phase voltage) [2], [10]- [12] . However, a higher dc-link voltage increases the rating of the VSI, makes the VSI heavy, and results in higher voltage rating of insulated gate bipolar transistor (IGBT) switches.…”
Section: Introductionmentioning
confidence: 99%
“…In this context, the most popular control technique is usually based on current controller which forces the SAPF current to follow its reference [7][8][9][10][11][12][13][14][15][16].…”
Section: Introductionmentioning
confidence: 99%
“…A number of control methods have been reported in the literature such as proportional-integral (PI) control [7], hysteresis control [7], dead-beat control [8], repetitive-based control [9], adaptive control [10], and nonlinear control [11]. Also, there has been tremendous progress during the last decade in current control techniques for active power filters [12][13][14][15][16] including of a proportional controller plus multiple sinusoidal signal integrators [12], a PI controller plus a series of resonant controllers [13,14], or vector PI (VPI) controllers [15].…”
Section: Introductionmentioning
confidence: 99%
“…Since three-phase diode rectifiers are widely used in industry, such as adjustable speed drives and dc power supplies (Thasananutariya and Chatratana, 2009;Chen and Luo, 2001;Grbovic et al, 2001), the harmonics generated by the diode rectifier in the line current is a main concern in power electronics. To eliminate the harmonic current generated by this type of harmonic source, the shunt Active Power Filter (APF) or series APF has been an effective solution (Corasaniti et al, 2009;Singh and Solanki, 2009;Lavopa et al, 2009;Rahmani et al, 2010;Vodyakho and Mi, 2009;Salmeron and Litran, 2010;Bhattacharya and Chakraborty, 2011). However, the rating of APF is normally small because of its partial power processing property.…”
Section: Introductionmentioning
confidence: 99%