Experimental determination of indoor air concentration of 5-chloro-2-methylisothiazol-3(2H)-one/ 2-methylisothiazol-3(2H)-one (CMIT/MIT) emitted by the use of humidifier disinfectant

Abstract: A mixture of 5-chloro-2-methylisothiazol-3(2H)-one/2-methylisothiazol-3(2H)-one (CMIT/MIT) had been used as an active ingredient in humidifier disinfectants (HDs). Owing to its high reactivity, the atmospheric concentration of CMIT/MIT, following its use in HD, would be lower than expected assuming that it is removed by ventilation only. In order to evaluate the exposure concentration of CMIT/MIT used as an HD, room-scale chamber studies were conducted under plausible use of three different HD doses at air cha… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 22 publications
1
8
0
Order By: Relevance
“…Thirdly, our estimated airborne levels of the mixture of CMIT and MIT to which HDLI patients were exposed (Table 4) are similar to the results (CMIT: 0.95-4.37 µg/m 3 , MIT: 0.30-1.75 µg/m 3 ) reported by Park et al (2020), who measured airborne CMIT and MIT using two serial impingers in a room-sized stainless steel chamber where HD containing the intended level was used [27]. This partly supports the validity of the assumptions for exposure assessment in this study, although there might be variations in exposure parameters among patients and potential losses of CMIT and MIT other than through ventilation.…”
Section: Discussionsupporting
confidence: 87%
“…Thirdly, our estimated airborne levels of the mixture of CMIT and MIT to which HDLI patients were exposed (Table 4) are similar to the results (CMIT: 0.95-4.37 µg/m 3 , MIT: 0.30-1.75 µg/m 3 ) reported by Park et al (2020), who measured airborne CMIT and MIT using two serial impingers in a room-sized stainless steel chamber where HD containing the intended level was used [27]. This partly supports the validity of the assumptions for exposure assessment in this study, although there might be variations in exposure parameters among patients and potential losses of CMIT and MIT other than through ventilation.…”
Section: Discussionsupporting
confidence: 87%
“…Changes in the ambient air concentration of test VOCs were measured in real-time using a custom-made chamber [ 18 ] ( Figure S1a ). A 30 m 3 stainless room-sized chamber was manufactured to meet the criteria set by the American Society for Testing and Materials (ASTM), and United States Environmental Protection Agency (U.S. EPA) [ 19 , 20 ].…”
Section: Methodsmentioning
confidence: 99%
“…Although the use of antibacterial substances is increasing globally, the systemic effects of IT biocides on human health are poorly understood [ 3 , 4 , 5 , 6 ]. These biocides can be absorbed orally and dermally during personal and industrial use [ 7 , 8 , 9 ] and subsequently circulate in the blood posing a human health risk [ 2 , 10 , 11 ]. While blood vessels are continuously exposed to circulating xenobiotics, the effects of IT biocides on the vascular system remain unknown.…”
Section: Introductionmentioning
confidence: 99%