2021
DOI: 10.1093/rpd/ncab052
|View full text |Cite
|
Sign up to set email alerts
|

Experimental Examination of Radiation Doses of Dual- And Single-Energy Computed Tomography in Chest and Upper Abdomen in a Phantom Study

Abstract: The aim of this phantom study is to examine radiation doses of dual- and single-energy computed tomography (DECT and SECT) in the chest and upper abdomen for three different multi-slice CT scanners. A total of 34 CT protocols were examined with the phantom N1 LUNGMAN. Four different CT examination types of different anatomic regions were performed both in single- and dual-energy technique: chest, aorta, pulmonary arteries for suspected pulmonary embolism and liver. Radiation doses were examined for the CT dose… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
2
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 47 publications
1
2
0
Order By: Relevance
“…CTM in dual-source mode is often preferred, especially in patients with postoperative status and metal implants after osteosynthesis, because it allows better beam hardening artifact suppression [6,20,21]. In the literature, studies on the impact of the dual-source mode on radiation exposure of CT are divergent [22]: our results, like other studies [23][24][25], show a slight dose increase, although in principle a comparable radiation exposure can also be achieved [26,27]. Radiation exposure on the SOMATOM Force was slightly lower in dual-source mode for CTM compared with the study of Grams et al [6].…”
Section: Discussionsupporting
confidence: 62%
“…CTM in dual-source mode is often preferred, especially in patients with postoperative status and metal implants after osteosynthesis, because it allows better beam hardening artifact suppression [6,20,21]. In the literature, studies on the impact of the dual-source mode on radiation exposure of CT are divergent [22]: our results, like other studies [23][24][25], show a slight dose increase, although in principle a comparable radiation exposure can also be achieved [26,27]. Radiation exposure on the SOMATOM Force was slightly lower in dual-source mode for CTM compared with the study of Grams et al [6].…”
Section: Discussionsupporting
confidence: 62%
“…Moreover, DE-CT limits the applicable pitch factor, which increases radiation dose and susceptibility to motion artifacts even further [22]. Hence, high-pitch low-kV single-phase aortic imaging has become the standard for EID-CTA [10,11,15,16,23] and is used for comparison to PCD-CTA in the present investigation.…”
Section: Discussionmentioning
confidence: 99%
“…For this purpose, reconstructions with a low keV level close to the k edge of iodine were generated from multienergetic spectral data to maintain the luminal attenuation despite reduced contrast agent dosage. One major disadvantage of DE-CT, however, lies in the higher radiation exposure per scan compared to single-energy CT, especially for abdominal CTA [9][10][11], although a dose benefit is achievable in multiphase scans due to virtual non-contrast reconstructions. Further limiting DE-CT for aortic CTA, image noise is considerably increased at low keV levels, subsequently hampering diagnostic assessability [12,13].…”
Section: Introductionmentioning
confidence: 99%