2010
DOI: 10.1016/j.enbuild.2010.06.014
|View full text |Cite
|
Sign up to set email alerts
|

Experimental investigation of a novel desiccant cooling system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 48 publications
(15 citation statements)
references
References 20 publications
0
15
0
Order By: Relevance
“…67 ω =ω (4) Supply air to the room is obtained by sensible cooling of air during 3-4 in cooling coil, which gives 34 ω =ω (5) Similarly, regeneration air is sensibly heated between 7-8 in an electric heater, giving 78 ω =ω (6) Energy balance between the two air streams in DW gives…”
Section: System Modelingmentioning
confidence: 99%
See 1 more Smart Citation
“…67 ω =ω (4) Supply air to the room is obtained by sensible cooling of air during 3-4 in cooling coil, which gives 34 ω =ω (5) Similarly, regeneration air is sensibly heated between 7-8 in an electric heater, giving 78 ω =ω (6) Energy balance between the two air streams in DW gives…”
Section: System Modelingmentioning
confidence: 99%
“…It has been evaluated that the hybrid solid desiccant cooling system achieves a higher part load performance in hot and humid climates. A hybrid solid desiccant air cooling system was designed and experimentally tested [6] for improving the air quality and to find out the reduction in energy consumption. Performance of a hybrid solid desiccant air conditioning system have been experimentally investigated [7] in terms of energy saving.…”
Section: Page 2 Of 43mentioning
confidence: 99%
“…It can be seen that DCHE combines advantages of conventional fin-tube heat exchanger which can effectively remove http://dx.doi.org/10.1016/j.ijheatmasstransfer.2015.06.033 0017-9310/Ó 2015 Elsevier Ltd. All rights reserved. sensible load and of solid desiccant material which can effectively remove latent load [14,15]. When two DCHEs are adopted to operate in parallel: one is in dehumidification process and the other is in regeneration process, a continuous operation air conditioning system can be achieved.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, experimental investigations included a novel desiccant based air conditioning system configuration to improve the indoor air quality and reduce energy consumption [25]. In the system studied, the moisture of the fresh air was reduced passing through a solid desiccant wheel and then its temperature decreased through the ''dry coil'' of a vapor compression cycle.…”
Section: Introductionmentioning
confidence: 99%