“…Experiment results showed that humidity ratio added to the process air could be higher than that removed by the desiccant wheel [23]. Performances can be improved using indirect evaporative coolers [25][26][27][28]. Jain and Dhar [7] found that coefficient of performance (COP) of systems with indirect evaporative coolers was significantly increased to over 1 from below 0.2 of the systems with direct evaporative coolers under constant t reg (130°C).…”
Section: Introductionmentioning
confidence: 93%
“…Experiment results showed that humidity ratio added to the process air could be higher than that removed by the desiccant wheel [23]. Performances can be improved using indirect evaporative coolers [25][26][27][28]. Jain and Dhar [7] found that coefficient of performance (COP) of systems with indirect evaporative coolers was significantly increased to over 1 from below 0.2 of the systems with direct evaporative coolers under constant t reg (130°C).…”
Section: Introductionmentioning
confidence: 93%
“…In this study, the supply air temperature could be cooled to around 14 • C when the initial temperature was 35 • C. According to the definition of thermal comfort zone for evaporative cooling applications by ASHRAE, this novel configuration could fully meet comfort conditions in hot and humid areas. Ali et al [73] performed a comprehensive study on the performance evaluation of the desiccant evaporative cooling system with different weather conditions. In this research work, five system configurations, including three standard systems and two modified systems, were assessed under five different climate zones via an equation-based object-oriented modeling and simulation method.…”
Section: Improvement In System Configurationmentioning
confidence: 99%
“…Different configurations of DEC based on operating cycle were investigated by Ali et al [112] in different Kӧppen climate zones, and results show that performance of ventilated cycle is more suitable in BWh(arid) and Cfa (semiarid), while ventilated Dunkel cycle for Dfb (temperate), Cwa (dry summer), and Csa (subtropical) are weather conditions as shown in Table 5.…”
Section: Comparison-based Studies On Sahdacmentioning