2006
DOI: 10.1016/j.mejo.2006.03.001
|View full text |Cite
|
Sign up to set email alerts
|

Experimental method and FE simulation model for evaluation of wafer probing parameters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2007
2007
2018
2018

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(7 citation statements)
references
References 5 publications
0
7
0
Order By: Relevance
“…In this study, an experiment using single probe test [6] was run to determine the stress distribution of die in probe test. A single-needle pins on die pad in an actual wafer level test.…”
Section: Probe Test Experimental Setupmentioning
confidence: 99%
See 1 more Smart Citation
“…In this study, an experiment using single probe test [6] was run to determine the stress distribution of die in probe test. A single-needle pins on die pad in an actual wafer level test.…”
Section: Probe Test Experimental Setupmentioning
confidence: 99%
“…They has point out the single-needle probe test results indicate that the contact force and scrub length increased when the overdrive increased. [6] This study are split into two components. One set of investigates an approach for the characterization of silicon die failure strength, employing a simple three-point bending test technique.…”
Section: Introductionmentioning
confidence: 99%
“…Several literatures (Bates, 1997;Comeau and Naduau, 1991;Chao et al, 2003;Liu and Shih, 2006) revealed that the contact force sensitivity is a function of the dimensions of probing needle, but none of them studied the effect of the geometric changes on the contact force and the forward displacement systematically. In this study, a finite element model of a cantilever needle was first constructed to simulate the stress distribution and the needle tip displacement during probing.…”
Section: Fig 1 -Epoxy Ring Probe Card For DVI Probing Test (Providedmentioning
confidence: 99%
“…Langlois et al (2003) focused their research on the probe card alignment technology to support the increasingly thorough testing and fast product cycle. Liu and Shih (2006) have set a single tungsten needle probe making contact with an Al pad was employed to investigate the relationships between the overdrive, contact force and scrub mark length. A 3-D FE model was also developed for analyzing the contact phenomena during wafer testing.…”
Section: Introductionmentioning
confidence: 99%
“…In the literature, usually the authors analyze the bond pad failure with static modeling, results might be correlated with experimental results [5,6]. Some studies point out the dynamic deformation of contact phenomenon with explicit finite elements analysis and investigate the scrub mark on the die [7,8]. The reaction force and dynamic behavior of needle is simulated by Schmadlak and al., they observe dynamic effects during the first 100µs after the impact time but its magnitude remains low [9].…”
Section: Probing Simulationmentioning
confidence: 99%