2012 China International Conference on Electricity Distribution 2012
DOI: 10.1109/ciced.2012.6508686
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study of the evaporative cooling system in a low-noise power transformer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 2 publications
0
2
0
Order By: Relevance
“…After introducing a new algorithm based on the reverse calculation method [17] or the corrections made of both ambient noise and sound wall reflections per the IEC (International Electrotechnical Commission) Standards [18], the accuracy of transformer noise measurements improves significantly. Moreover, from the manufacturer point of view, considering the low-frequency noise of electrical substation was always presented and noticed in daily lives of residents near the source [19], the structural optimization and low-or ultra-low-noise power transformers design by means of acoustic radiation model arouses designer's attention gradually [20], to meet the increasingly stringent environmental standards, the improved core assembling form [21], and even optimized cooling system arrangement form [22] are taken into account by manufacturers.…”
Section: Introductionmentioning
confidence: 99%
“…After introducing a new algorithm based on the reverse calculation method [17] or the corrections made of both ambient noise and sound wall reflections per the IEC (International Electrotechnical Commission) Standards [18], the accuracy of transformer noise measurements improves significantly. Moreover, from the manufacturer point of view, considering the low-frequency noise of electrical substation was always presented and noticed in daily lives of residents near the source [19], the structural optimization and low-or ultra-low-noise power transformers design by means of acoustic radiation model arouses designer's attention gradually [20], to meet the increasingly stringent environmental standards, the improved core assembling form [21], and even optimized cooling system arrangement form [22] are taken into account by manufacturers.…”
Section: Introductionmentioning
confidence: 99%
“…In the decades of research progress, the durability and aging resistance of fluorocarbon coolant have also been tested and a lot of engineering practice experience and technical reserves have been accumulated, which provides a solid foundation for the application of evaporative cooling technology in transformer. The evaporative cooling transformer has also been made a subject of preliminary application attempt in the early stage [8,9]. At present, the research and development of conventional evaporative cooling transformer is relatively backward because of the high cost of coolant.…”
Section: Introductionmentioning
confidence: 99%