2018
DOI: 10.1016/j.expthermflusci.2017.10.034
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study of vortex tube energy separation under different tube design

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
18
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 63 publications
(19 citation statements)
references
References 21 publications
1
18
0
Order By: Relevance
“…Higher pressure results in lower temperature of the cold outlet. Hamdan which has performed an experiment with different dimensions and forms of vortex tube also found for the pressure at 2bar, 3bar, and 4bar [7]. However an anomaly was found at 5bar pressure.…”
Section: Presentation Of Experimental Datamentioning
confidence: 81%
See 1 more Smart Citation
“…Higher pressure results in lower temperature of the cold outlet. Hamdan which has performed an experiment with different dimensions and forms of vortex tube also found for the pressure at 2bar, 3bar, and 4bar [7]. However an anomaly was found at 5bar pressure.…”
Section: Presentation Of Experimental Datamentioning
confidence: 81%
“…Changes in temperature and coefficient of performance refrigeration (COPref) are also influenced by mass fractions [3][4][5][6]. Other vortex tube performance parameters are pressure, whereas the higher pressure results in lower temperature [4][5]7].…”
Section: Introductionmentioning
confidence: 99%
“…Accordingly, choosing the codes of connection type and nozzle materials which are negative multipliers in the regression equation will lead to an increase in ∆T value. When the previous studies are examined, it is seen that increasing inlet pressure and number of orifices improves the performance of RHVTs [14][15][16] and that metal-based nozzle material gives better results than plastic-based one [15,17]. In addition, it is also seen from the previous studies that connection types in RHVTs influence their performance and that parallel connections increase the ∆T values [23].…”
Section: Multiple Linear Regression Analysismentioning
confidence: 90%
“…al evaluated the performances of vortex tubes in different geometric parameters (length, diameter and taper of the pipe) and different inlet pressures. Following the experimental study, they stated that the inlet pressure was considerably effective on vortex tube performance [16]. Kırmacı et.…”
Section: Introductionmentioning
confidence: 99%
“…So far there are very plenty of available researches to validate the reliability of CFD analyses for investigating the flow and temperature inside vortex tube. Mohammad O. Hamdan et al [4] studied the effect of vortex tube length on the performance of vortex tube. The research was conducted under pressure of 4bar using a vortex tube with three different length; 66 mm, 113mm and 158 mm.…”
Section: Fig 1 Schematic Diagram Of Vortex Tube [1]mentioning
confidence: 99%