2018
DOI: 10.1016/j.tust.2017.08.025
|View full text |Cite
|
Sign up to set email alerts
|

Experimental study on color change and compression strength of concrete tunnel lining in a fire

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 35 publications
(6 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…Typical concrete specimens were tested under dif ferent elevated temperatures, as seen in Figure 2. MIRA is a low frequency (20-100 kHz multifunctional phased array ultrasonic system that can be used to detect objects, inter faces, and anomalies in concrete structures [30]. Since the ultrasonic probes in MIRA do not require a coupling gel to ensure the transmission of waves into the concrete, the probe can be moved from one position to the next position with almost no surface preparation Shear wave velocity is 2160 m/s.…”
Section: Upv Test and Shear-wave Tomography Equipmentmentioning
confidence: 99%
See 1 more Smart Citation
“…Typical concrete specimens were tested under dif ferent elevated temperatures, as seen in Figure 2. MIRA is a low frequency (20-100 kHz multifunctional phased array ultrasonic system that can be used to detect objects, inter faces, and anomalies in concrete structures [30]. Since the ultrasonic probes in MIRA do not require a coupling gel to ensure the transmission of waves into the concrete, the probe can be moved from one position to the next position with almost no surface preparation Shear wave velocity is 2160 m/s.…”
Section: Upv Test and Shear-wave Tomography Equipmentmentioning
confidence: 99%
“…The evaluation of the residual tensile strength of fire-damaged concrete using a non-linear resonance vibration method was proposed [29]. A tricolor image processing method was proposed to analyze the color changes in the concrete lining of tunnels and to evaluate the damage caused by fire [30]. UPV is the most promising NDT method that has been used to establish an accurate relationship between the RCS and the UPV propagation in concrete after exposure to elevated temperatures.…”
Section: Introductionmentioning
confidence: 99%
“…This package enabled us to measure the intensity of various component colors in regions of interest (ROIs). After that, the ultrasonic test was conducted; changes in ultrasonic waves can reflect the internal degradation of the concrete structure and predict internal collapse [26][27][28][29]. A Tektronix AFG3022B arbitrary waveform generator and Tektronix TDS1002B-SC provided the source and receiver signals, respectively, as digital oscilloscope in this experiment (Fig.…”
Section: Testing Proceduresmentioning
confidence: 99%
“…Previous research studies have mainly focused on the fire performance of isolated members of shield tunnel. On the experimental side, various studies have been conducted to support grading evaluations and analysis of structural safety of lining structures in fire (Du et al, 2018;Qiao et al, 2019;Tomar and Khurana, 2019;Yan et al, 2012;Zhang et al, 2021c;e). Only a small number of experimental studies have been carried out on a whole tunnel structure setting in fire due to high costs.…”
Section: Introductionmentioning
confidence: 99%