2022
DOI: 10.1016/j.apenergy.2021.118242
|View full text |Cite
|
Sign up to set email alerts
|

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(5 citation statements)
references
References 24 publications
1
4
0
Order By: Relevance
“…Table 7 shows the comparisons between the present calculation results and the data obtained from the references. It can be seen that the present mathematical model results showed a good agreement with the corresponding results from the works of Saleh [60] and Grauberger et al [26]. As a result of this, the present mathematical model can be accepted as validated.…”
Section: Validation Of the Present Modelsupporting
confidence: 88%
See 2 more Smart Citations
“…Table 7 shows the comparisons between the present calculation results and the data obtained from the references. It can be seen that the present mathematical model results showed a good agreement with the corresponding results from the works of Saleh [60] and Grauberger et al [26]. As a result of this, the present mathematical model can be accepted as validated.…”
Section: Validation Of the Present Modelsupporting
confidence: 88%
“…Although there is not any study considering the same configuration with the proposed combined system in this study, there are some studies considering combined ORC-VCRC systems in the current literature. Hence, two recently reported works about the combined systems by Saleh [60] and Grauberger et al [26] are chosen for the validation of the present model. The configurations and operating conditions of these combined systems were taken as defined in the references.…”
Section: Validation Of the Present Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…The results showed that the R245fa exhibited the highest thermal efficiency of 25%, which was 29% higher than the 19.4% achieved using R1234yf under the same operating conditions. Grauberger et al [49] designed and evaluated an experimental ORC-VCRC of 300 kWth using novel heat integration strategies. The system uses a turbo-compressor sharing a single shaft.…”
Section: Integrated Cooling and Power Systemsmentioning
confidence: 99%
“…From the literature reviewed, it is clear that there have been many studies of ORC driven with solar energy [60] for a wide range of applications. Also, many studies have been reported for the simultaneous production of power and cooling, but most of these studies integrate a VCRC into an ORC [47,49,50]. Also, many systems have used an ERC for cooling purposes [51][52][53].…”
Section: Integrated Cooling and Power Systemsmentioning
confidence: 99%