2019
DOI: 10.1016/j.optlastec.2018.11.036
|View full text |Cite
|
Sign up to set email alerts
|

Extended the linear measurement range of four-quadrant detector by using modified polynomial fitting algorithm in micro-displacement measuring system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 31 publications
(9 citation statements)
references
References 11 publications
0
9
0
Order By: Relevance
“…The proposed precision level was calibrated by a commercial autocollimator (AutoMAT Co. model 5000U; resolution: 0.01 arc-sec; accuracy: ±0.1 arc-sec; repeatability: 0.05 arc-sec; uncertainty: 0.119 arc-sec). It is known that the output signal of QPD will show obvious nonlinearity in a large range [22]. In order to obtain the most suitable linear sensitivity coefficient on different measurement ranges, the two inclined directions of the dual-axis precision level were calibrated for the different measurement ranges of ±100 arc-sec, ±400 arc-sec, and ±800 arc-sec, separately.…”
Section: Calibration Resultsmentioning
confidence: 99%
“…The proposed precision level was calibrated by a commercial autocollimator (AutoMAT Co. model 5000U; resolution: 0.01 arc-sec; accuracy: ±0.1 arc-sec; repeatability: 0.05 arc-sec; uncertainty: 0.119 arc-sec). It is known that the output signal of QPD will show obvious nonlinearity in a large range [22]. In order to obtain the most suitable linear sensitivity coefficient on different measurement ranges, the two inclined directions of the dual-axis precision level were calibrated for the different measurement ranges of ±100 arc-sec, ±400 arc-sec, and ±800 arc-sec, separately.…”
Section: Calibration Resultsmentioning
confidence: 99%
“…Phase Kinoform [25] 100.0 32-Level [5,6,29,30] 99.7 16-Level [5,6,29,30] 98.7 8-Level [5,6,29,30] 95.0 4-Level [5,6,29,30] 81.1 2-Level [15,25] 40.5 Sinusoidal [25] 33.9 Amplitude 2-Level [27,33] 10.1 Sinusoidal [25][26][27][28] 6.25…”
Section: Types Diffractive Lenses Efficiency (%)mentioning
confidence: 99%
“…The researchers, Liu et al [32], Liang et al [20], Vo et al [33], Li et al [34], Aguilar et al [35], Zhang et al [36], Chen et al [37], Ünal et al [1], and Zhang et al [38], have conducted various investigations related to the beam size on 4-quadrant detectors, enhancing the linear measurement range, studying the measurement sensitivity of Gaussian and Laguerre-Gaussian beams on 4-quadrant detectors, expanding the linear measurement range, and examining the effects of a non-uniform spot on 4-quadrant detectors.…”
Section: Introductionmentioning
confidence: 99%
“…Laser light sources used in laser spot trackers generally employ pulse lasers operating from several Hz to tens of Hz, and laser receivers consist of a photodetector with an optical system, four photodiode arrays, and an amplifier that converts photocurrents into voltage and amplifies the voltage. [5][6][7] Although a constant signal can be acquired using a laser spot tracker at a fixed condition indoors, the laser signal received may vary according to the performance and position of the laser spot tracker and transmitter, target size, reflectance and angle, atmospheric conditions, and solar spectral irradiance using a laser spot tracker outdoors. In particular, solar spectral irradiance diminishes the detection range because it produces noise in addition to the hardware noise of the laser spot tracker.…”
Section: Introductionmentioning
confidence: 99%