/npsi/ctrl?lang=en http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/ctrl?lang=fr Access and use of this website and the material on it are subject to the Terms and Conditions set forth at http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/jsp/nparc_cp.jsp?lang=en
NRC Publications Archive Archives des publications du CNRCThis publication could be one of several versions: author's original, accepted manuscript or the publisher's version. / La version de cette publication peut être l'une des suivantes : la version prépublication de l'auteur, la version acceptée du manuscrit ou la version de l'éditeur. For the publisher's version, please access the DOI link below./ Pour consulter la version de l'éditeur, utilisez le lien DOI ci-dessous.http://dx.doi.org/10.1177/1744259112450419Journal of Building Physics, 36, 3, pp. 308-329, 2012-12-23 Thermal performance of wall assemblies with low emissivity Saber, Hamed H.
ABSTRACTIn wall systems, airspaces can increase thermal resistance if a reflective material such as foil with low emissivity is installed in a Furred-Airspace Assembly (FAA). In this paper, the present model, hygIRC-C, was used to investigate the steady-state thermal resistance of wall assemblies that incorporate foil adhered to expanded polystyrene (EPS) foam in a furredassembly. To investigate the effect of the furring orientation, the furring was installed horizontally and vertically and compared to walls with no furring. For wall with vertical furring, the 3D version of the present model was used to capture the 3D effect of the thermal bridges. Because the foil emissivity can be affected by dust accumulation and/or water vapor condensation on the foil surface, consideration was given to investigate the effect of both varying foil emissivity and outdoor temperature on the thermal performance of the various wall specimens. Results showed that the thermal resistance (R-value) of the reference wall (no furring) is greater than the wall specimens with furring. A lso, results showed that the contribution of the FAA to the R-value of wall specimen with vertical furring is higher than that for wall specimen with horizontal furring.