Extracorporeal pumpless interventional lung assist in clinical practice: determinants of efficacy

Abstract: Respiratory acidosis can become a serious problem during protective ventilation of severe lung failure. A pumpless arteriovenous interventional lung assist (iLA) for extracorporeal carbon dioxide removal has been used increasingly to control critical respiratory situations. The present study sought to evaluate the factors determining the efficacy of iLA and calculate its contribution to gas exchange.In a cohort of 96 patients with severe acute respiratory distress syndrome, haemodynamic parameters, oxygen cons… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
54
0
9

Year Published

2012
2012
2023
2023

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 83 publications
(65 citation statements)
references
References 33 publications
2
54
0
9
Order By: Relevance
“…10 Yine bu çalışmada, ILA'dan geçen kan akımının önemli olduğu, kalp debisinin, ortalama arter basıncının korunması gerektiği vurgulanmış-tır. Kopp ve ark.…”
Section: Olgu Sunumuunclassified
“…10 Yine bu çalışmada, ILA'dan geçen kan akımının önemli olduğu, kalp debisinin, ortalama arter basıncının korunması gerektiği vurgulanmış-tır. Kopp ve ark.…”
Section: Olgu Sunumuunclassified
“…The system's oxygen transfer capacity is physically limited and achieves no more than 10% to 15% of total oxygen consumption (14). Severe hypoxemia is therefore a contraindication for iLA; ECMO is indicated instead.…”
Section: Indications and Contraindicationsmentioning
confidence: 99%
“…The flow rate of oxygen is increased in a stepwise fashion up to a maximum of 12 L/min. The shunt is usually created between the femoral 6 demonstrated that: • The primary determinants of blood flow through the system are: the dimensions of the cannulae (in accordance with the Hagen-Poisseuille equation), the arteriovenous pressure gradient (rather than cardiac output), and the resistance of the membrane.…”
Section: Av-ecco 2 Rmentioning
confidence: 99%
“…The previously mentioned study by Muller et al looked specifically at the O 2 and CO 2 transfer that occurred via the Novalung iLA ® (AV-ECCO 2 R) in 96 patients with ARDS. 6 Blood samples were taken before and after the AV-ECCO 2 R device in order to calculate the O 2 and CO 2 content of blood at these points. The flow of blood through the device was also measured and hence the rate of gas transfer could be calculated using Fick' s principle.…”
Section: Oxygenationmentioning
confidence: 99%