2019
DOI: 10.1016/j.ultsonch.2019.104710
|View full text |Cite
|
Sign up to set email alerts
|

Extraction of high-amylose starch from Radix Puerariae using high-intensity low-frequency ultrasound

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
20
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 29 publications
(24 citation statements)
references
References 53 publications
3
20
1
Order By: Relevance
“…RS4 (Fibersym® RW) was obtained from commercial sources (Atchison, KS, U.S.A.), which consisted 20.83% of amylose, 0.09% of protein, 0.16% of fat, 1.07% of ash, 0.36% of phosphorus as determined following the iodine colorimetric reaction [15] and AOAC protocol [17] , respectively. Fibersym was cross-linked phosphorylated normal wheat starch and retained the granular form [5] .…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…RS4 (Fibersym® RW) was obtained from commercial sources (Atchison, KS, U.S.A.), which consisted 20.83% of amylose, 0.09% of protein, 0.16% of fat, 1.07% of ash, 0.36% of phosphorus as determined following the iodine colorimetric reaction [15] and AOAC protocol [17] , respectively. Fibersym was cross-linked phosphorylated normal wheat starch and retained the granular form [5] .…”
Section: Methodsmentioning
confidence: 99%
“…The apparent amylose content of samples was determined using iodine colorimetric reaction based on a previous study with slightly modifications [15] . Briefly, starch samples (50 mg) including amylose and amylopectin standards were dissolved in 9 mL of KOH (2 mol/L) and 1 mL of ethanol.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Let be K 4 ¼ K d K m (15) where K 4 was the inactivation constant (h −1 ) of Alcalase during enzymatic hydrolysis of pretreated OVA by Alcalase. The formula (15) was brought in (9) and (10):…”
Section: Calculation Of Kinetic Constantsmentioning
confidence: 99%
“…[14] In general, depending on the ultrasonic frequency and intensity, ultrasound can be divided into low-and high-intensity approaches in the food industry. [15] Many researchers used HIU, which use acoustic frequencies between 20 and 100 kHz, to alter the molecular characteristics in order to get much better functional properties of food protein. Albano and Nicoletti [16] reported that the ultrasound can increase emulsion stability due to the increase in apparent viscosity caused by droplet size reduction and consequent increase of interfacial area.…”
Section: Introductionmentioning
confidence: 99%