2019
DOI: 10.1109/tuffc.2019.2906134
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication and Characterization of a Miniaturized 15-MHz Side-Looking Phased-Array Transducer Catheter

Abstract: This paper describes the development of a miniaturized 15-MHz side-looking phased-array transducer catheter. The array features a 2-2 linear composite with 64 piezoelectric elements mechanically diced into a piece of PMN-30% PT single crystal and separated by nonconductive epoxy kerfs at a 50-µm pitch, yielding a total active aperture of 3.2 mm in the azimuth direction and 1.8 mm in the elevation direction, with an elevation natural focal depth of 8.1 mm. The array includes nonconductive epoxy backing and two … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(10 citation statements)
references
References 26 publications
1
9
0
Order By: Relevance
“…For the transducer, the measurement of − 6 dB directivity was ± 30 • , as shown in Figure 11, which can serve satisfactorily in the performance of phased-array beam. Similar results were reported with directivity of approximately ±25 • for a 2-2 composite phased array (Bezanson et al, 2014;Cabrera-Munoz et al, 2019).…”
Section: Basic Performance Of Phased-array Transducersupporting
confidence: 89%
See 2 more Smart Citations
“…For the transducer, the measurement of − 6 dB directivity was ± 30 • , as shown in Figure 11, which can serve satisfactorily in the performance of phased-array beam. Similar results were reported with directivity of approximately ±25 • for a 2-2 composite phased array (Bezanson et al, 2014;Cabrera-Munoz et al, 2019).…”
Section: Basic Performance Of Phased-array Transducersupporting
confidence: 89%
“…Currently, many researchers have focused their efforts on the development of miniaturized phased-array transducer (Bezanson et al, 2014;Chiu et al, 2014;Basij et al, 2019;Cabrera-Munoz et al, 2019). The current manufacturing process of the transducer is rather cumbersome.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Based on the porcine carotid artery phantom imaging evaluation results, the array provided a penetration depth > 5 mm for IVUS imaging. Following this work, Cabrera-Munoz et al [141] fabricated a 15 MHz side-looking phased array transducer as well, which was composed of 64-element of 2-2 PMN-PT composite. The fabricated array showed an aperture of 3.2 mm × 1.8 mm, which could be integrated into a 10 Fr catheter.…”
Section: Single Frequency Arraymentioning
confidence: 99%
“…This is the reason why 3D ultrasound imaging methods based on 2-D array probes are continuing to improve in terms of fabrication and processing [7,8], and synthetic aperture ultrasound imaging [9,10]. Recently, the combination of miniaturized phased-array transducers and minimally invasive robotic surgery instruments is a further challenge in array development; preliminary phantom measurements demonstrate the feasibility to provide intraoperative image guidance and tissue characterization during endoscopic procedures [11].…”
Section: Ultrasound Imaging 21 Piezoelectric Transducers Technologymentioning
confidence: 99%