2019
DOI: 10.1016/j.jtice.2019.08.004
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication of a biocompatible and continuous glucose biosensor with the poly(3,4-ethylenedioxythiophene) modified electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 27 publications
0
8
0
Order By: Relevance
“…Besides, some characteristic bands related to oxygen functional groups were found at 3500, 1580, 1270, and 1072 cm −1 , which might also contribute to the higher O/S element ratio in EDS analysis. Lines b demonstrated the typical spectra of PEDOT, which including asymmetric stretching vibrations of C=C and C–C in the thiophene ring at 1528 and 1372 cm −1 , bend vibration of C–O–C in the ethylenedioxy ring at 1220 and 1062 cm −1 , stretching vibrations of C–S–C bond in the thiophene ring at 980, 850, and 696 cm −1 , and possible deformation of the ethylenedioxy ring at 920 cm −1 [ 35 , 40 , 41 ]. The FTIR spectrum of PEDOT remained almost the same after HQ measurement as shown by line c, indicating the good stability of PEDOT film on the PL electrode.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Besides, some characteristic bands related to oxygen functional groups were found at 3500, 1580, 1270, and 1072 cm −1 , which might also contribute to the higher O/S element ratio in EDS analysis. Lines b demonstrated the typical spectra of PEDOT, which including asymmetric stretching vibrations of C=C and C–C in the thiophene ring at 1528 and 1372 cm −1 , bend vibration of C–O–C in the ethylenedioxy ring at 1220 and 1062 cm −1 , stretching vibrations of C–S–C bond in the thiophene ring at 980, 850, and 696 cm −1 , and possible deformation of the ethylenedioxy ring at 920 cm −1 [ 35 , 40 , 41 ]. The FTIR spectrum of PEDOT remained almost the same after HQ measurement as shown by line c, indicating the good stability of PEDOT film on the PL electrode.…”
Section: Resultsmentioning
confidence: 99%
“…Recently, we have also developed a green chemical process by using non-thermal plasma activated hydrogen peroxide to promote the synthesis of PEDOT and demonstrated the degradability of PEDOT [ 51 , 52 ]. Meanwhile, we have employed PEDOT to modify a platinum electrode to construct biosensors for sensing hydrogen peroxide and glucose [ 31 , 32 , 35 ]. So far, PEDOT has been proposed for a great variety of promising applications in bioelectronics, conductive hydrogel, and other functional materials [ 53 , 54 , 55 , 56 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…A LOD of 0.1 μM with a linear range of 2 × 10 −6 –4.5 × 10 −3 M, and a repeatability of 7.1% as RSD ( n = 5) for 5 mM glucose in the presence of 0.5 mM of AA and UA. PEDOT films were electrochemically deposited on a Pt electrode with bovine serum albumin as a platform for Pt/PEDOT-BSA/AuNP-GOx sensors [ 169 ]. FTIR, analysis shows no disruption of PEDOT film by the posterior modifications.…”
Section: Electrochemical Sensors Based On Conducting Polymersmentioning
confidence: 99%