2017
DOI: 10.1088/2053-1591/aa764e
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication of a cost-effective polymer nanograting as a disposable plasmonic biosensor using nanoimprint lithography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 44 publications
0
7
0
Order By: Relevance
“…SPR seems to be an extremely significant situation, as label-free detection methods have been discovered to be effective and accurate for clinical analysis and molecular reactions [1][2][3]. The prism coupling strategy is the greatest widely utilized approach for (SP) generation across all SPR techniques.…”
Section: Fig 1: Surface Plasmon Wave In Gold Film By Using Kretschman...mentioning
confidence: 99%
See 1 more Smart Citation
“…SPR seems to be an extremely significant situation, as label-free detection methods have been discovered to be effective and accurate for clinical analysis and molecular reactions [1][2][3]. The prism coupling strategy is the greatest widely utilized approach for (SP) generation across all SPR techniques.…”
Section: Fig 1: Surface Plasmon Wave In Gold Film By Using Kretschman...mentioning
confidence: 99%
“…The prism is coated with gold film (50 𝑛𝑚) that gathers evanescent waves generated by total reflections and releases. The gold/air boundary is used to release the SP wave once the angle is adjusted at a given value which is illustrated in figure (3). The photodiode sensor measures the amount of light that is reflected from the interface.…”
Section: Fig 1: Surface Plasmon Wave In Gold Film By Using Kretschman...mentioning
confidence: 99%
“…𝑆𝑃𝑅 becomes a more common occurrence as that was discovered that label-free detection techniques are appropriate and dependable for clinical analysis and biomolecular interactions. The SPR device's performance (sensitivity) is determined by metal layer optimization [5][6][7][8][9]. It has been observed that a material has the lowest amount of reflection at a given angle (resonance angle) compared to the other angle [10].…”
Section: Introductionmentioning
confidence: 99%
“…Many of these fabrication methods of gratings consist of several steps, which leads to a longer time required to structure fabrication. There have been presented interesting results of grating-coupled SPR sensors employing grating structures, mainly one-dimensional (1D) [ 26 , 27 , 28 , 29 , 30 , 31 ]. There is an effort to achieve grating-based sensors with high sensitivity and easy and cheap fabrication.…”
Section: Introductionmentioning
confidence: 99%
“…The grating-coupled SPR sensors were used as temperature sensors [ 21 ], RI sensors [ 24 , 25 , 33 , 35 ] and as biosensors [ 10 , 18 , 19 , 32 , 36 , 37 , 38 , 39 , 40 ]. Gold-coated polymer gratings brought an efficient way for fabrication of SPR gratings instead of using thick metal layers [ 29 , 30 , 35 , 41 , 42 , 43 ]. Although many of the presented SPR structures are large-scale, the reduction in their dimensions is needed for microfluidic and lab-on-a-chip (LOC) devices.…”
Section: Introductionmentioning
confidence: 99%