Fabrication of a liquid-gated enzyme field effect device for sensitive glucose detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(11 citation statements)
references
References 27 publications
0
11
0
Order By: Relevance
“…DEP has been proven as an adaptable mechanism to transportation, accumulation, separation and characterization of submicron bio-particles in microfluidic systems. The integration of DEP systems into the microfluidics provides the inexpensive, fast, highly sensitive, selective and label-free detection of bio-species [15][16][17][18][19][20][21][22][23].…”
Section: Dielectrophoresismentioning
confidence: 99%
“…DEP has been proven as an adaptable mechanism to transportation, accumulation, separation and characterization of submicron bio-particles in microfluidic systems. The integration of DEP systems into the microfluidics provides the inexpensive, fast, highly sensitive, selective and label-free detection of bio-species [15][16][17][18][19][20][21][22][23].…”
Section: Dielectrophoresismentioning
confidence: 99%
“…There would be a charge transfer from the H 2 O 2 molecules to the MoS 2 channel. 26,27,[44][45][46][47][48][49] The glucose oxidation reaction is as follows:…”
Section: Detection Of Glucose Using Mos 2 Fet Based Biosensormentioning
confidence: 99%
“…As shown in Table 2, the proposed ZnO-based glucose biosensor shown higher sensitivity, 28 shorter response time 45 and wider linear dynamic range 50 than those previous reports. 26,27,46,47,[51][52][53][54][55] And the detection limit of the reduced graphene oxide/carboxylated polypyrrole nanotube (rGO/C-PPy NT) FET based biosensor 42 was better than other glucose biosensors. [26][27][28][45][46][47][50][51][52][53][54][55] Compared with previous researches, the bilayer MoS 2 -based FET we prepared show signicant advantages in high sensitivity detection of extremely low concentration glucose solution.…”
Section: Sensitivity Testmentioning
confidence: 99%
“…A transducer transforms the indication arising from the interaction of the analyte with the component into a quantiable signal, such as current or voltage, which can be determined effortlessly. 7 D-Glucose (D-GLC) is a preliminary energy source of the human body, and helps in the formation of metabolic intermediates. However, an inappropriate concentration of D-GLC in blood leads to diabetes mellitus and can cause various complications, such as blindness, cardiac, ocular, and peripheral vascular diseases, stroke, and kidney failure.…”
Section: Introductionmentioning