2005
DOI: 10.1016/j.snb.2005.02.014
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication of miniature Clark oxygen sensor integrated with microstructure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
73
0
8

Year Published

2007
2007
2021
2021

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 101 publications
(83 citation statements)
references
References 25 publications
2
73
0
8
Order By: Relevance
“…To improve the selectivity and avoid contamination of electrodes by the samples, an oxygen permeable membrane is overlaid on the electrodes, and usually a reservoir of sample solution is located on top of the oxygen permeable membrane to contain the sample solution under test. The mode of operation of the Clark sensor is amperometric [25,26]. The dissolved oxygen is brought to the surface of WE and a negative voltage is applied between the WE and CE.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…To improve the selectivity and avoid contamination of electrodes by the samples, an oxygen permeable membrane is overlaid on the electrodes, and usually a reservoir of sample solution is located on top of the oxygen permeable membrane to contain the sample solution under test. The mode of operation of the Clark sensor is amperometric [25,26]. The dissolved oxygen is brought to the surface of WE and a negative voltage is applied between the WE and CE.…”
Section: Introductionmentioning
confidence: 99%
“…Clark sensor has many applications in biosensor development, clinical analysis and fermentation monitoring [2,26]. Miyahara et al characterized size, linearity, selectivity, reproducibility, and response time as some of the main properties to determine the ability of the Clark sensor to measure dissolve oxygen [29].…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, the need for a positioning system (Rosa and Yu 2006), along with its high cost and fragility (Wu et al 2005) make profile recording with Clark-type microsensors a delicate and tedious process, and one that requires a major investment of both time and resources.…”
Section: Introductionmentioning
confidence: 99%
“…Nesta parte do trabalho foi projetado e fabricado um sistema optoeletrônico portátil colorimétrico e fluorimétrico, utilizando-se como detector um sistema multiespectral, WU et al, 2005). Porém, e em geral, os sensores baseados em resposta elétrica e eletroquímica apresentam tempos de resposta elevados e degradação rápida (WU et al, 2005).…”
Section: Conclusõesunclassified
“…Porém, e em geral, os sensores baseados em resposta elétrica e eletroquímica apresentam tempos de resposta elevados e degradação rápida (WU et al, 2005).…”
Section: Conclusõesunclassified