1985
DOI: 10.1097/00000542-198511000-00002
|View full text |Cite
|
Sign up to set email alerts
|

Factors Influencing Pulmonary Volumes and CO2 Elimination during High-frequency Jet Ventilation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

6
60
1
14

Year Published

1986
1986
2012
2012

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 119 publications
(81 citation statements)
references
References 0 publications
6
60
1
14
Order By: Relevance
“…There are several reasons to suggest that the same level of PG resulted in similar increase in mean lung volume in the three modes of ventilation. First, we previously demonstrated that when HFJV is applied to patients with decreased lung compliance, the gradient between upper airway pressure and alveolar pressure is minimum (2,17,18). Second, patients with asthma or chronic obstructive pulmonary disease were excluded.…”
Section: Discussionmentioning
confidence: 99%
“…There are several reasons to suggest that the same level of PG resulted in similar increase in mean lung volume in the three modes of ventilation. First, we previously demonstrated that when HFJV is applied to patients with decreased lung compliance, the gradient between upper airway pressure and alveolar pressure is minimum (2,17,18). Second, patients with asthma or chronic obstructive pulmonary disease were excluded.…”
Section: Discussionmentioning
confidence: 99%
“…In general, CPAP application to the nondependent lung is useful for preventing arterial desaturation during OLV. On the other hand, HFJV has been shown to recruit alveoli through the PEEP effect it generates [7], and this method could reopen some lung areas and reduce the risk of arterial hypoxemia during OLV. Crimi et al [8] reported a dramatic improvement in arterial oxygenation and unchanged hemodynamics with the application of HFJV to the nondependent lung and ventilation of the dependent lung with intermittent positive pressure, in patients with one-lung injury.…”
Section: Discussionmentioning
confidence: 99%
“…Insbesondere bei kleinem Tubus-Innendurchmesser kann es durch den eingelegten Jetkatheter zur Blockade des Luftausstroms kommen, was zu einer plötzlichen Überblähung der Lunge und damit zu einer erheblichen Behinderung des chirurgischen Vorgehens führen kann. Hohe Beatmungsfrequenzen können die Hyperinflation begün-stigen [8], besonders gefährdet sind auch Asthmatiker [15]. Aus Sicherheitsgründen dürfen deshalb heute nur noch solche Jet-Generatoren verwendet werden, welche über einen automatischen Abschaltmechanismus verfügen.…”
Section: Beatmungssituation (In Beiden Fällen) Die Oben Liegende (Reunclassified