Abstract:Given the failure of reverse cut-off seal performance in the test process of the check valve, the fault location and mechanism analysis were carried out, and the improvement measures were proposed and verified by the test. It is analyzed that the main reason for the failure is the unreasonable design of the moving pair and the welding position of the check valve, which makes the sealing pair cannot fit effectively after the welding of the check valve, leading to the failure of the reverse cut-off seal. By cont… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.