2013
DOI: 10.1103/physreva.88.043815
|View full text |Cite
|
Sign up to set email alerts
|

Faraday and Cotton-Mouton effects of helium atλ=1064nm

Abstract: We present measurements of the Faraday and the Cotton-Mouton effects of helium gas at λ = 1064 nm. Our apparatus is based on an up-to-date resonant optical cavity coupled to longitudinal and transverse magnetic fields. This cavity increases the signal to be measured by more than a factor of 270 000 compared to the one acquired after a single path of light in the magnetic field region. We have reached a precision of a few percent both for Faraday effect and Cotton-Mouton effect. Our measurements give for the fi… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
32
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(35 citation statements)
references
References 24 publications
3
32
0
Order By: Relevance
“…The integration time was T = 4 hours. Given that F = 6.7 × 10 5 , λ = 1064 nm, B 2 dl = 10.25 T 2 m, from the amplitude of the He peak at 32 µbar, the value of ∆n u for helium results ∆n (He,PVLAS) u = (2.2 ± 0.1) × 10 −16 T −2 atm −1 , in perfect agreement with other published values [6,28,29]. It must be noted that this value is obtained from a single low pressure point.…”
Section: Calibrationsupporting
confidence: 78%
See 2 more Smart Citations
“…The integration time was T = 4 hours. Given that F = 6.7 × 10 5 , λ = 1064 nm, B 2 dl = 10.25 T 2 m, from the amplitude of the He peak at 32 µbar, the value of ∆n u for helium results ∆n (He,PVLAS) u = (2.2 ± 0.1) × 10 −16 T −2 atm −1 , in perfect agreement with other published values [6,28,29]. It must be noted that this value is obtained from a single low pressure point.…”
Section: Calibrationsupporting
confidence: 78%
“…The magnetic birefringence of gases also depends linearly on pressure. In Table V the equivalent partial pressures P eq which would mimic a vacuum magnetic birefringence for various gases [6,[28][29][30] are reported. The vacuum system must maintain these species well below their vacuum equivalent pressures.…”
Section: Polarizersmentioning
confidence: 99%
See 1 more Smart Citation
“…[5], one has to consider systematic effects that mimic the CM effect we want to measure. We thus derive a more general expression taking into account the symmetry properties of Y j towards experimental parameters:…”
Section: Data Analysis and Resultsmentioning
confidence: 99%
“…[3,4,5]. A linearly polarized Nd:YAG laser beam (λ = 1064 nm) goes through an acousto-optic modulator (AOM) used in double passage for an adjustment of the laser frequency.…”
Section: Methodsmentioning
confidence: 99%