Fast and accurate islanding detection technique for microgrid connected to photovoltaic system

Abstract: Islanding condition means the case of feeding the loads from any distributed generator (DG) with a complete disconnection of the utility grid at the point of common coupling. The main technical issue in DG integration with the primary grid is the islanding condition. Hence, islanding must be detected using an appropriate anti-islanding technique which is needed to be faster in terms of time detection and accuracy. This paper illustrates the phenomenon of islanding and the passive methods which are used for pre… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
29
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(29 citation statements)
references
References 26 publications
0
29
0
Order By: Relevance
“…In addition, the ROCOV and VoI thresholds have been tuned based on the off-line simulations, which depend largely on the studied test system. Elshrief et al adopted the rate of change of active power (ROCOP) and PCC voltage deviation for islanding detection purposes [29]. According to the presented MATLAB/Simulink simulations, this technique fails to detect a well-balanced island as the employed variable hardly deviates in such scenarios.…”
Section: Protection Relays Based On Time-domain Variablesmentioning
confidence: 99%
See 2 more Smart Citations
“…In addition, the ROCOV and VoI thresholds have been tuned based on the off-line simulations, which depend largely on the studied test system. Elshrief et al adopted the rate of change of active power (ROCOP) and PCC voltage deviation for islanding detection purposes [29]. According to the presented MATLAB/Simulink simulations, this technique fails to detect a well-balanced island as the employed variable hardly deviates in such scenarios.…”
Section: Protection Relays Based On Time-domain Variablesmentioning
confidence: 99%
“…As mentioned in the last subsection, standards and system operators have emphasised the importance of providing Maxima of superimposed voltage components [25] CRPH [26] Piecewise P DG vs. V PCC function [27] ROCOV and VoI [28] PR controller feedback [30] PCC voltage ripple [24] ROCOP and ROCOV [29] UVP/OVP [15] PI controller saturation [31] Several cases…”
Section: Applicable For Standalone Microgridmentioning
confidence: 99%
See 1 more Smart Citation
“…There have been lots of methods to detect the networks' operation mode known as island detection methods. These methods utilized non-phasor measurements of network parameters and characteristics analyses [6]- [15], or phasor measurements data obtained from phasor measurement units (PMUs) [16]- [18].…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, by offline modeling and online monitoring, the islanding situation is detected. As a recent non-phasor based method, the islanding mode is detected using the rate of change of power technique based on the terminal voltage of the DG [15]. Also, lots of research have been introduced for island detection that are based on phasor measurements.…”
Section: Introductionmentioning
confidence: 99%