Fast iterative pre‐emphasis calibration method enabling third‐order dynamic shim updated fMRI

Abstract: The proposed method enables accurate pre-emphasis calibration, and therefore, the application of dynamic shim updating to fMRI.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
45
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 22 publications
(45 citation statements)
references
References 26 publications
0
45
0
Order By: Relevance
“…These functions are used to create a linear time-invariant model of all coil-field dynamics which can then be inverted to obtain pre-emphasis waveforms that null all unwanted dynamics. This approach has been used to achieve 0th–3rd order shim updating with settling times on the order of 1 ms (Vannesjo et al, 2016) or 2 ms (Fillmer et al, 2016). Field camera-monitored dynamic 1st–3rd order SH shimming has been used to acquire fMRI time series EPI slices (Fillmer et al, 2016) that show no visible eddy current artifacts.…”
Section: Overview Of B0 Shim Field Generation Hardwarementioning
confidence: 99%
See 2 more Smart Citations
“…These functions are used to create a linear time-invariant model of all coil-field dynamics which can then be inverted to obtain pre-emphasis waveforms that null all unwanted dynamics. This approach has been used to achieve 0th–3rd order shim updating with settling times on the order of 1 ms (Vannesjo et al, 2016) or 2 ms (Fillmer et al, 2016). Field camera-monitored dynamic 1st–3rd order SH shimming has been used to acquire fMRI time series EPI slices (Fillmer et al, 2016) that show no visible eddy current artifacts.…”
Section: Overview Of B0 Shim Field Generation Hardwarementioning
confidence: 99%
“…This approach has been used to achieve 0th–3rd order shim updating with settling times on the order of 1 ms (Vannesjo et al, 2016) or 2 ms (Fillmer et al, 2016). Field camera-monitored dynamic 1st–3rd order SH shimming has been used to acquire fMRI time series EPI slices (Fillmer et al, 2016) that show no visible eddy current artifacts. Notably, limitations on shim amplifier voltage and current headroom prevented the full benefit of the pre-emphasis from being realized in these experiments.…”
Section: Overview Of B0 Shim Field Generation Hardwarementioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, only three translation and three rotation parameters τ=[x,y,z,θ,φ,ρ] need to be found to find the optimal positions of all the field probes. The optimization problem from Equation then becomes: minτ=[x,y,z,θ,φ,ρ]p=1Npbold-italicfmeasγGfalse(r(bold-italicτ)false)2. …”
Section: Methodsmentioning
confidence: 99%
“…An advantage of MC shim arrays are their intrinsic similarity to multi‐element receive and transmit RF coil arrays. As a natural extension of this latter concept, a merging both of RF and shim functions into a single device has recently been proposed by several groups . The advantage of such a combined device is the prospect for efficient packaging into a single closely coupled (tight fitting) coil array.…”
Section: Introductionmentioning
confidence: 99%