2002
DOI: 10.1002/mrm.10285
|View full text |Cite
|
Sign up to set email alerts
|

Fast phase‐contrast velocity measurement in the steady state

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
36
0

Year Published

2004
2004
2009
2009

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(38 citation statements)
references
References 28 publications
2
36
0
Order By: Relevance
“…They are being used for different applications and have replaced older GRE sequences. Numerous studies have reported the advantageous applications of SSFP in cardiac imaging [13,14,15,23,24,25,26]. Newer developments also allow for the use of SSFP in viability diagnostics.…”
Section: Clinical Impact Of Mri First-pass Perfusionmentioning
confidence: 95%
“…They are being used for different applications and have replaced older GRE sequences. Numerous studies have reported the advantageous applications of SSFP in cardiac imaging [13,14,15,23,24,25,26]. Newer developments also allow for the use of SSFP in viability diagnostics.…”
Section: Clinical Impact Of Mri First-pass Perfusionmentioning
confidence: 95%
“…Nevertheless, if these higher harmonics are clinically significant, they could be obtained either by reducing to twofold acceleration or by decreasing the TR. Because standard CINE PC measurements with TR as low as 6 ms can be made with a reasonable SNR (14), the fourfold acceleration approach could be performed with a cutoff frequency as high as 10.4 Hz, allowing approximately 10 harmonics to be obtained. Alternatively, if only four harmonics are of interest, a TR of 6 ms could conceivably be used in a 10-fold-accelerated protocol.…”
Section: Discussionmentioning
confidence: 99%
“…In terms of M and HR, this yields a Ͻ 1/͑4 TR M HR). [14] which reflects the maximum acceleration factor for obtaining M harmonics. Alternatively, a larger acceleration factor can be used if high-frequency velocity components occupy only a portion of space.…”
Section: Hp-lp Combined With Unfoldmentioning
confidence: 99%
“…The conventional approach to flow quantification utilizes spoiled gradient echo (GE) imaging technique, which inherently has a limited signal-to-noise ratio (SNR) when applied with short repetition times. With the advent of faster gradient systems flow quantification with steady-state free precession (SSFP) sequences has become feasible, three different approaches were published by Overall et al [5], Markl et al [6] and Pai [7]. Advantages of SSFP are shorter acquisition times and higher SNR [8,9].…”
Section: Introductionmentioning
confidence: 97%