Fast protocol for radiochromic film dosimetry using a cloud computing web application

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 21 publications
0
6
0
Order By: Relevance
“…Measurements of the OF for the IMRT– and SBRT–style fields (Table 1 ) were carried out using EBT3 radiochromic film (Ashland Inc., Wayne, NJ, USA). Film was used according to recommendations from the manufacturer and the literature [ 13 ], and to our previous experience [ 14 ].…”
Section: Methodsmentioning
confidence: 99%
“…Measurements of the OF for the IMRT– and SBRT–style fields (Table 1 ) were carried out using EBT3 radiochromic film (Ashland Inc., Wayne, NJ, USA). Film was used according to recommendations from the manufacturer and the literature [ 13 ], and to our previous experience [ 14 ].…”
Section: Methodsmentioning
confidence: 99%
“…with RC software the agreement is between 87.6% and 99.8% using fast protocol for IMRT plans with 3%, 3 mm criteria and 10% threshold. 41 …”
Section: Discussionmentioning
confidence: 99%
“…Gafchromic EBT3 film (Ashland, Bridgewater, NJ, USA) 37 , 38 was normally used for high-resolution dose measurement free of washing, presenting many attractive characteristics compared to other dosimeters: high spatial resolution, weak energy dependence in a wide photon energy range, near tissue-equivalence, small dose rate and fractionation dependence, no angular dependence. The film reading process was composed of 3 steps: 1. lot calibration with film strips; 2. film scanning and reading; and 3. film calibration and gamma evaluation.…”
Section: Methodsmentioning
confidence: 99%
“…In steps 1 and 2, Epson 800 (Epson, Long Beach CA, USA) was adopted as the film scanner, and the scanning for film strips and films was performed both prior to and after irradiation, using a resolution of 50 dpi, 48-bit full-color, reflection mode, and multichannel dosimetry (all red–green–blue channels), with all color corrections in the scanner turned off. In step 3, www.radiochromic.com , a Food and Drug Administration-approved online web application was used as a film calibration and analysis tool to analyze measured in-plane dose distribution on the film 37 , 38 and the functionality of lateral correction for the film was enabled in this software.…”
Section: Methodsmentioning
confidence: 99%