Fast Transient Modulation for a Step Load Change in a Dual-Active-Bridge Converter with Extended-Phase-Shift Control

Abstract: Abstract:The manipulation of the bidirectional power in a dual-active-bridge converter relies on the adjustment of several phase-shift angles. Improper implementation of those adjustments during the transient process of a step load change may induce transient DC bias current in the transformer and accompanied high peak current, which may result in excess loss and safety issues potentially. The paper proposes a load transient modulation to execute the adjustments of the two phase-shift angles for extended-phase… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 12 publications
(13 citation statements)
references
References 33 publications
0
13
0
Order By: Relevance
“…The instant currents after the intermediate adjustment are calculated as: To minimize the transient period, the same requirement shown in Equation (15) should be met. Combining Equations (7), (8), (17), (18) and (15), the intermediate switching angles for transition from mode A to mode B are given as:…”
Section: Load Transient Control From Mode a To Mode Bmentioning
confidence: 99%
See 1 more Smart Citation
“…The instant currents after the intermediate adjustment are calculated as: To minimize the transient period, the same requirement shown in Equation (15) should be met. Combining Equations (7), (8), (17), (18) and (15), the intermediate switching angles for transition from mode A to mode B are given as:…”
Section: Load Transient Control From Mode a To Mode Bmentioning
confidence: 99%
“…Based on SPS control, a transient control named asymmetric-double-side modulation proposed in [16] distributes the required phase-shift adjustment to both two bridges according to an optimized ratio to depress the DC bias current in the transition process. The same technique is then extended to EPS control in [17,18]. However, the obtained results in [17] can not deal with the operation when the converter gain is close to unity.…”
Section: Introductionmentioning
confidence: 99%
“…However, the response time to a load change command would be long. In the literature, there are different types of solutions reported [16][17][18][19][20][21][22][23][24][25][26]. The direct flux control is costly with an extra magnetic sensor and associated connection.…”
Section: Introductionmentioning
confidence: 99%
“…This modulation operates by using the Phase-Shift (ϕ) between output voltages of the bridges, as in the PS modulation, along with the pulse width variation of the Bridge 1 output voltage (D 1 ), being D 2 = 1, Figure 2b. EPS modulation reduces the circulating energy and the conduction losses for medium power, therefore improving the performance compared to the PS modulation [15][16][17][18][19], although with a reduced impact for low power.…”
Section: Introductionmentioning
confidence: 99%