2014
DOI: 10.1111/echo.12695
|View full text |Cite
|
Sign up to set email alerts
|

Feasibility of Perflutren Microsphere Contrast Transthoracic Echocardiography in the Visualization of Ventricular Endocardium during Venovenous Extracorporeal Membrane Oxygenation in a Validated Ovine Model

Abstract: Despite exposure to destructive hydrodynamic forces, CE is a feasible technique in an ovine ECMO model. CE results in significantly improved EDS and increased EL.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1
1

Relationship

3
5

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 38 publications
0
10
0
Order By: Relevance
“…Our results corroborate previously described quantification of microbubble destruction in an ECMO circuit, both in vitro and in an ovine model. 24,25 Unlike previous studies, we were able to document the rate of UCA destruction by the oxygenator alone using US to continuously measure bubble destruction in a closed in vitro circuit, eliminating the interference of additional support equipment, interactions within the patient or animal, general shear forces, and microbubble instability. We observed a relatively small absolute decrease of UCA intensity across the oxygenator over time, with further microbubble destruction likely attributable to the additional circuit equipment.…”
Section: Discussionmentioning
confidence: 99%
“…Our results corroborate previously described quantification of microbubble destruction in an ECMO circuit, both in vitro and in an ovine model. 24,25 Unlike previous studies, we were able to document the rate of UCA destruction by the oxygenator alone using US to continuously measure bubble destruction in a closed in vitro circuit, eliminating the interference of additional support equipment, interactions within the patient or animal, general shear forces, and microbubble instability. We observed a relatively small absolute decrease of UCA intensity across the oxygenator over time, with further microbubble destruction likely attributable to the additional circuit equipment.…”
Section: Discussionmentioning
confidence: 99%
“…There is limited data on the safety and efficacy of contrast echocardiography in patients supported with mechanical cardiac support. It has been shown to be feasible in an ovine ECMO model [ 49 ] as well as limited description of its use in the clinical setting [ 50 53 ].…”
Section: Discussionmentioning
confidence: 99%
“…Along with laser Doppler flowmetry, it is an ideal imaging modality for studying the microcirculation of organ blood flow/velocity patterns [ 141 , 142 ]. Unlike other modalities CEU is safe, free of disruptive haemodynamic effects, and easy to utilise in patients on ECMO; however investigation into the destructive effects of the circuit interface on the concentration and utility of the contrast microspheres is warranted [ 143 145 ]. Due to logistical and incompatibility issues related to the ECMO circuit, recent advancements in other imaging modalities cannot be utilised to investigate EAKI.…”
Section: Methods For Investigating Ecmo-associated Kidney Injurymentioning
confidence: 99%