Feasibility of using ultra‐low pulse rate fluoroscopy during routine diagnostic coronary angiography

Abstract: IntroductionCoronary angiogram, while a powerful diagnostic tool in coronary artery disease, is not without an associated risk from ionising radiation. There are a number of factors that influence the amount of radiation the patient receives during the procedure, some of which are under the control of the operator. One of these is an adjustment of the fluoroscopic pulse rate. This study aims to assess the feasibility of using ultra‐low pulse rate (3 pulses per second(pps)) fluoroscopy during routine diagnostic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
18
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(18 citation statements)
references
References 12 publications
0
18
0
Order By: Relevance
“…The side effects of radiation exposure include cancer, cataracts, non-malignant skin damage, and impaired fertility ( 3 ). Several studies have confirmed the increased incidence of cancer as well as posterior subcapsular lens opacities in interventional cardiologists ( 4 ). There are also concerns over the possibility of a causal relationship between left sided brain tumors and occupational radiation exposure in interventional cardiologists ( 5 ).…”
Section: Introductionmentioning
confidence: 90%
“…The side effects of radiation exposure include cancer, cataracts, non-malignant skin damage, and impaired fertility ( 3 ). Several studies have confirmed the increased incidence of cancer as well as posterior subcapsular lens opacities in interventional cardiologists ( 4 ). There are also concerns over the possibility of a causal relationship between left sided brain tumors and occupational radiation exposure in interventional cardiologists ( 5 ).…”
Section: Introductionmentioning
confidence: 90%
“…It depends mainly on individual application settings. Thus, algorithms developed to support diagnostic angiography, performed with the aim of subsequent emergent blood ow restoration, should correspond to the following requirements: input video frame rate of 7.5-15 frames per second 39,40 , the duration of the procedure less than 25 minutes, and individual preferences of the operator 41 . We concluded that neural network architectures with an inference time of less than 66 milliseconds are suitable for this task (Table 4.…”
Section: Image Processing Speedmentioning
confidence: 99%
“…The study by Badawy et al also has implications for the radiation dose to the staff present, particularly the primary operator, who stands closest to the patient during these procedures. Radiation exposure to staff working in cath labs can be significant.…”
Section: Implications For Staff Radiation Dosementioning
confidence: 99%
“…The paper by Badawy et al demonstrates the impact that proactive staff working in the cath lab can have on the radiation exposure of the patient. Using an X‐ray system ‘straight out of the box’ without some form of customisation to the local environment is ill‐advised.…”
Section: Radiation Safety Implicationsmentioning
confidence: 99%
See 1 more Smart Citation