2007
DOI: 10.1007/s10661-007-9921-x
|View full text |Cite
|
Sign up to set email alerts
|

Field evaluation of a tailor-made new passive sampler for the determination of NO2 levels in ambient air

Abstract: This study describes the field evaluation of a tailor-made new glass passive sampler developed for the determination of NO(2), based on the collection on triethanolemine (TEA)-coated fibre filter paper. The sampler has been derived from a Palmes design. The overall uncertainty of the sampler was determined by using Griess-Saltzman ASTM D 1607 standard test method as a reference method. The agreement between the results of the passive sampler and the reference method was +/-7.90% with the correlation coefficien… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 38 publications
0
7
0
Order By: Relevance
“…50 lL of 20 % TEA (Ozden and Dogeroglu 2007;Varshney and Singh 2003) was added to each filter type which was contained in a polypropylene (PP) diffusion tube (5.3 cm long and 1.3 cm i.d.). A sampling set consisted of five sampling tubes and three blanks (unopened tube).…”
Section: Selection Of Sorbentmentioning
confidence: 99%
See 3 more Smart Citations
“…50 lL of 20 % TEA (Ozden and Dogeroglu 2007;Varshney and Singh 2003) was added to each filter type which was contained in a polypropylene (PP) diffusion tube (5.3 cm long and 1.3 cm i.d.). A sampling set consisted of five sampling tubes and three blanks (unopened tube).…”
Section: Selection Of Sorbentmentioning
confidence: 99%
“…Behavior of the TEA absorbents and chemical interferences of NO 2 measurements were studied in the UK (Kirby et al 2000). A new passive sampler for NO 2 monitoring was developed by Ozden and Dogeroglu (2007). Passive samplers for atmospheric pollutants such as SO 2 , NO 2 , O 3 and H 2 S in tropical areas were developed and validated by Campos et al (2010).…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Ozden and Dogeroglu [49] describe a field evaluation in Eskisehir, Turkey, of a tailor-made glass passive sampler for NO 2 . This is not a Palmes-type PDT but is similar in concept, and the authors also deployed standard Gradko PDTs.…”
Section: Field Studiesmentioning
confidence: 99%