2014
DOI: 10.5731/pdajpst.2014.00973
|View full text |Cite
|
Sign up to set email alerts
|

Filling of High-Concentration Monoclonal Antibody Formulations into Pre-Filled Syringes: Filling Parameter Investigation and Optimization

Abstract: Syringe filling can be considered a well-established manufacturing process and has been implemented by numerous contract manufacturing organizations and biopharmaceutical companies. However, its technical details and associated critical process parameters are rarely published. The information on high-concentration/viscosity formulation filling is particularly lacking. The purpose of this study is three-fold: (1) to reveal design details of a bench-top syringe filling unit; (2) to identify and optimize critical… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(4 citation statements)
references
References 9 publications
0
4
0
Order By: Relevance
“…The development of high-concentration mAbs can pose significant challenges to product development pertaining to stability, manufacturability, and processing. High-concentration mAb formulation in a prefilled syringe are well documented; however increased injection force for syringes with high fluid viscosity along withformulation stability is particularly challenging ( 6 ).…”
Section: Introductionmentioning
confidence: 99%
“…The development of high-concentration mAbs can pose significant challenges to product development pertaining to stability, manufacturability, and processing. High-concentration mAb formulation in a prefilled syringe are well documented; however increased injection force for syringes with high fluid viscosity along withformulation stability is particularly challenging ( 6 ).…”
Section: Introductionmentioning
confidence: 99%
“…A recent study using mAb formulated at 180 mg/mL investigated the key parameters for successful filling of the mAb into a prefilled syringe (Shieu et al, 2014). The key parameters investigated were solution viscosity, concentration, and surface tension.…”
Section: Filling Of Highly Concentrated Mabs Into Prefilled Syringesmentioning
confidence: 99%
“…Additionally, for high protein concentration formulations, the suck-back (pump-reversal) on peristaltic pumps must be carefully controlled to avoid droplet formation on the end of the filling needle, which is prone to rapid drying and clogging of the filling needles during the process. 65,66 The time-pressure filling system is another technology that has gained increasing popularity in the pharmaceutical industry. One of the benefits of this system is reduced product contact parts and the absence of surface-to-surface contact (grinding) during the filling process.…”
Section: Fillingmentioning
confidence: 99%