Volume 1: Codes and Standards 2007
DOI: 10.1115/pvp2007-26100
|View full text |Cite
|
Sign up to set email alerts
|

Final Proposal of Environmental Fatigue Life Correction Factor (Fen) for Structural Materials in LWR Water Environment

Abstract: Low cycle fatigue life of structural materials diminishes remarkably as functions of various parameters in high temperature water simulating LWR coolant. Such reduction was estimated by the fatigue life reduction factor (Fen) and the equations to calculate Fen were developed and have undergone revision over the past ten years. The authors have endeavored to establish the method assessing fatigue damage at LWR power plants for the past 13 years in the Japanese EFT (Environmental Fatigue Tests) project under the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
8
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 13 publications
(11 citation statements)
references
References 0 publications
3
8
0
Order By: Relevance
“…In addition, the results of LCF test with mixed strain rate (0.24-0.024%/s) also indicate that the fatigue life in air is not dependent on strain rate. Both observations are consistent with the previous results by ANL [1][2][3][4], Japanese researchers [5][6][7], and authors [13,14]. Fig.…”
Section: Test Conditions and Methodssupporting
confidence: 95%
See 3 more Smart Citations
“…In addition, the results of LCF test with mixed strain rate (0.24-0.024%/s) also indicate that the fatigue life in air is not dependent on strain rate. Both observations are consistent with the previous results by ANL [1][2][3][4], Japanese researchers [5][6][7], and authors [13,14]. Fig.…”
Section: Test Conditions and Methodssupporting
confidence: 95%
“…5 shows the fatigue life of 316LN SS tested in RT air and 310°C air with a constant strain and mixed strain rates. According to the published LCF results, the fatigue life of austenitic SSs in air is not dependent on strain rate or temperature [1][2][3][4][5][6][7]. Before the mixed strain rate tests in PWR water, we performed a few tests at a strain rate of 0.024%/s to confirm such behaviors for 316LN SS.…”
Section: Test Conditions and Methodsmentioning
confidence: 86%
See 2 more Smart Citations
“…Vibration magnitude and frequency are calculated with computational flow dynamics (CFD) codes for singleand two-phase flows and then the calculated results are applied to estimate the residual lifetime by using the fatigue curves approved by the American Society of Mechanical Engineers (ASME) with environmental factors to calibrate corrosion factors. 9,10) The procedures for FIV due to single-phase flow are a proven type of approach (Fig. 4).…”
Section: Major Factors That Determine Structural Materials Problemsmentioning
confidence: 99%